Re: Strange networking issue

From: John Jolet (john.jolet_at_FXFN.COM)
Date: 04/28/03

  • Next message: Naylor, Jim: "Re: Non-Interactive SFTP"
    Date:         Mon, 28 Apr 2003 09:09:28 -0500
    To: aix-l@Princeton.EDU
    
    

    for a test, route add -host (man route, i think). to make it stick across reboots, after your test, do a route delete, then use smit to add it (communications->tcpip->further configuration->static routes)

    -----Original Message-----
    From: Willeat, Todd [mailto:TWilleat@MHP.SMHS.COM]
    Sent: Friday, April 25, 2003 3:05 PM
    To: aix-l@Princeton.EDU
    Subject: Re: Strange networking issue

    The traceroute from the Win2K box to the AIX box SHOULD have just one entry.
    But I get the same thing as AIX to Win2K - 30 rows of * * * Request timed
    out.

    No static routes have been added. Where you you put them?

    -----Original Message-----
    From: John Jolet [mailto:john.jolet@FXFN.COM]
    Sent: Friday, April 25, 2003 10:13 AM
    To: aix-l@Princeton.EDU
    Subject: Re: Strange networking issue

    well, when you have multiple interfaces in the box, i think routing does
    happen, even if it's local....the traceroute from the win2k box just has one
    entry...the aix box, right? I know it sounds silly, but have you tried
    adding a static route to the win2k box gated via the correct aix interface?

    -----Original Message-----
    From: Willeat, Todd [mailto:TWilleat@MHP.SMHS.COM]
    Sent: Thursday, April 24, 2003 11:56 PM
    To: aix-l@Princeton.EDU
    Subject: Re: Strange networking issue

    There shouldn't be any routing since both boxes are on the same subnet...
    But, if it helps, here's the traceroute info:

    trying to get source for mhp-aquaman
    source should be 170.29.112.254
    traceroute to mhp-aquaman (170.29.112.30) from 170.29.112.254
    (170.29.112.254), 30 hops max
    outgoing MTU = 1500
     1 * * *
     2 * * *
     3 * * *
     4 * * *
     5 * * *
     6 * * *
     7 * * *
     8 * * *
     9 * * *
    10 * * *
    11 * * *
    12 * * *
    13 * * *
    14 * * *
    15 * * *
    16 * * *
    17 * * *
    18 * * *
    19 * * *
    20 * * *
    21 * * *
    22 * * *
    23 * * *
    24 * * *
    25 * * *
    26 * * *
    27 * * *
    28 * * *
    29 * * *
    30 * * *

    -----Original Message-----
    From: John Jolet [mailto:john.jolet@FXFN.COM]
    Sent: Thursday, April 24, 2003 8:16 PM
    To: aix-l@Princeton.EDU
    Subject: Re: Strange networking issue

    really, really sounds like a routing issue...what does a traceroute from the
    aix to win2k box look like?

    -----Original Message-----
    From: Willeat, Todd [mailto:TWilleat@MHP.SMHS.COM]
    Sent: Thursday, April 24, 2003 5:22 PM
    To: aix-l@Princeton.EDU
    Subject: Strange networking issue

    Hi all,

    I have a strange network connectivity issue between a p640 box (AIX 4.3.3
    ML11) and a Win2K box (SP3). Both boxes are on the same subnet (and same
    switch), but are having problems pinging each other. The Win2K box has no
    problem connecting to other boxes, and people can telnet to the AIX box. The
    Win2K box has 6 GigE connections in an 802.3ad dynamic team. The p640 box
    has a SysKonnect dual-port GigE card running in failover mode (as well as
    the 2 integrated 10/100s - I have one of these on another subnet and the
    Win2K box can ping that just fine...). Looking at the arp tables shows that
    each box knows the other's MAC address. My network admin captured some
    packets between the 2 and this is what we saw:

    Pinging from Win2K to AIX - we saw the packet go from Win2K to AIX, but AIX
    did not return any packets.
    Pinging from AIX to Win2K - we saw the packet go from AIX to Win2K and saw
    the response packet from Win2K to AIX, but AIX did not receive it (request
    timed out).

    It appears that AIX is dropping the packets from this Win2K box for some
    reason (I have several other p640s with the same config that work fine).
    However, when I rebooted the Win2K box (after it locked up...), I could then
    ping between the boxes. But this only lasted for a day or so, and now it is
    not working again.

    Has anyone seen anything like this before?

                   _______________________________________
                  / Todd A. Willeat \
                 | UNIX Administrator |
                 | Mercy Health Plans |
                 | 425 South Woods Mill Road |
               _ | Chesterfield, Missouri 63017-3492 | _
              / )| (314) 214-2329 / (314) 214-8202 (fax) |( \
             / / | twilleat@mhp.mercy.net | \ \
           _( (_ | http://www.mercyhealthplans.com/ | _) )_
          (((\ \> \/->___________<-=-=-=-=->___________<-\/ </ /)))
          (\\\\ \_/ / \ \_/ ////)
           \ / \ /
            \ _/ \_ /
            / / \ \
           /___/ \___\

    This e-mail contains information which (a) may be PROPRIETARY IN NATURE OR
    OTHERWISE PROTECTED BY LAW FROM DISCLOSURE, and (b) is intended only for the
    use of the addressee (s) named above. If you are not the addressee, or the
    person responsible for delivering this to the addressee (s), you are hereby
    notified that reading, copying or distributing this e-mail is prohibited. If
    you have received this e-mail in error, please contact the sender
    immediately.


  • Next message: Naylor, Jim: "Re: Non-Interactive SFTP"

    Relevant Pages

    • Re: Strange networking issue
      ... IBM Certified Specialist AIX Administration ... Subject: Strange networking issue ... I added the route and it still didn't work, ... Win2K again and I could ping the AIX! ...
      (AIX-L)
    • Re: Strange networking issue
      ... Subject: Strange networking issue ... All switch ports are set to 1000/Full. ... AIX is set to sense switch port. ... not be coded properly to 1gb full on the AIX/ether switch/ WIN2K? ...
      (AIX-L)
    • Re: Strange networking issue
      ... Subject: Strange networking issue ... But, if it helps, here's the traceroute info: ... I have a strange network connectivity issue between a p640 box (AIX ... The Win2K box has ...
      (AIX-L)
    • Re: Strange networking issue
      ... Subject: Strange networking issue ... yes, there should be no routing, but it is! ... I have a strange network connectivity issue between a p640 box (AIX ... The Win2K box has ...
      (AIX-L)
    • Re: Strange networking issue
      ... Subject: Strange networking issue ... Yes same subnet, but what subnet is the 10/100 interface on. ... on the same physical network the packet will never get back to the Win2K ... To fix that set up a static route on the AIX box. ...
      (AIX-L)