Re: SSA Cache battery replacement

From: Adams Kevin J (kevin.adams_at_PHS.COM)
Date: 05/30/03

  • Next message: Adams Kevin J: "Re: SSA Cache battery replacement"
    Date:         Fri, 30 May 2003 08:44:05 -0700
    To: aix-l@Princeton.EDU
    
    

    The command is documented in the Advanced SerialRAID Adapters User's Guide
    and Maintenance Information, SA33-3285-01.

    Kevin Adams
    PacifiCare Behavioral Health
    Principal Systems Analyst
    AIX Certified Advanced Technical Expert
    -----Original Message-----
    From: Darryl Ousterhout [mailto:D.Ousterhout@LABSAFETY.COM]
    Sent: Friday, May 30, 2003 6:59 AM
    To: aix-l@Princeton.EDU
    Subject: Re: [aix-l] SSA Cache battery replacement

    Mat,

    The batteries typically have about 1000 hours of use left in them after the
    first error is generated in the error report. We had a CE come in and
    replace all of ours, we had 6 that failed at the exact same time. Afterwards
    he ran an apparently undocumented (that's what he said) command: ssa_format
    -l ssa# -b

    Where # is obviously the SSA loop that the FWC resides on. If your sick of
    seeing errors in the errpt, you can run this anytime to reset the battery
    timer, just remember it really does need replacement eventually.

    Regards,
    Darryl
    -----Original Message-----
    From: Gipson, Mat [mailto:Mat.Gipson@AMERICREDIT.COM]
    Sent: Friday, May 30, 2003 8:18 AM
    To: aix-l@Princeton.EDU
    Subject: SSA Cache battery replacement

    Question for all of you... How do I "reset" a F/W cache battery? I replaced
    the burned out battery and it still shows the old battery statistics...i.e.
    battery hours.

    Any help is greatly appreciated!

    Mathew Gipson
    matt.gipson@americredit.com <mailto:matt.gipson@americredit.com>
    817.525.7123

    This electronic message transmission, including any attachments, contains information from PacifiCare Health Systems Inc. which may be confidential or privileged. The information is intended to be for the use of the individual or entity named above. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the contents of this information is prohibited.

    If you have received this electronic transmission in error, please notify the sender immediately by a "reply to sender only" message and destroy all electronic and hard copies of the communication, including attachments.


  • Next message: Adams Kevin J: "Re: SSA Cache battery replacement"

    Relevant Pages

    • Re: SSA Cache battery replacement
      ... SSA Cache battery replacement ... IBM AIX Discussion List ...
      (AIX-L)
    • Re: SSA Cache Battery
      ... Could anyone who has successfully ordered these SSA batteries from IBM ... > Subject: SSA Cache Battery ... > error log that you should change the SSA Cache battery? ... The security of electronic mail sent through the Internet ...
      (AIX-L)
    • Re: sparc 20 workstation time
      ... > I issue the command as man page, the problem is the year is still in 1970. ... > So, I would like to know it is battery problem, should I change the clock ... power off) and remove the old one, replacing it with a new one. ... can use OBP commands and/or "eeprom" Solaris command to change values. ...
      (comp.sys.sun.misc)
    • Re: sparc 20 workstation time
      ... > I issue the command as man page, the problem is the year is still in 1970. ... > So, I would like to know it is battery problem, should I change the clock ... power off) and remove the old one, replacing it with a new one. ... can use OBP commands and/or "eeprom" Solaris command to change values. ...
      (comp.unix.admin)
    • Re: sparc 20 workstation time
      ... > I issue the command as man page, the problem is the year is still in 1970. ... > So, I would like to know it is battery problem, should I change the clock ... power off) and remove the old one, replacing it with a new one. ... can use OBP commands and/or "eeprom" Solaris command to change values. ...
      (comp.unix.solaris)