Errors on fiber channel adapter.

From: James Jackson (James.Jackson_at_MAIL.STATE.AR.US)
Date: 07/31/03

  • Next message: Peter McKay: "Re: FAStT 600 and AIX"
    Date:         Thu, 31 Jul 2003 16:20:31 -0500
    To: aix-l@Princeton.EDU
    
    

    Gurus,

    I have an M80 with a pair of 6228 FC adapters. One of the adapters is
    sending periodic FSCSI_ERR2's accompanied by occasional SC_DISK_ERR4's
    from its child "hdisks". The adapters are connected to an F20 ESS via a
    SAN. I'm using SDD for path redundancy, and I have a single volume group
    which contains two vpaths. Each vpath has six "hdisks", three from each
    6228. I need to run diag on the flaky 6228, but I don't want to varyoff
    the volume group. Does anyone know if the following procedure will work
    as a means of getting the 6228 in a state that'll support diag?

    * run "datapath set adapter 1 offline", which will cease SDD I/O
    to adapter 1, setting its hdisks' state to "DEAD".
    * run "rmdev -l" on the child hdisks and fscsi1 device.

    If this works, will the following procedure get everything back to
    normal?

    * run "cfgmgr -l fcs1".
    * run "datapath set adapter 1 online".

    TIA,

    James Jackson

    Confidentiality Notice: The information contained in this email message
    and any attachment(s) is the property of the State of Arkansas and may
    be protected by state and federal laws governing disclosure of private
    information. It is intended solely for the use of the entity to whom
    this email is addressed. If you are not the intended recipient, you are
    hereby notified that reading, copying or distribution of this
    transmission is STRICTLY PROHIBITED. The sender has not waived any
    applicable privilege by sending the accompanying transmission. If you
    have received this transmission in error, please notify the sender by
    return e-mail and delete the message and attachment(s) from your system.


  • Next message: Peter McKay: "Re: FAStT 600 and AIX"