Re: SAN Adapter Stats

From: Clifton, Pablo (Pablo.Clifton_at_BCBSFL.COM)
Date: 02/25/04

  • Next message: Jason delaFuente: "Re: SAN Adapter Stats"
    Date:         Wed, 25 Feb 2004 16:54:00 -0500
    To: aix-l@Princeton.EDU
    
    

    Jason-

    Try nmon from IBM (select "a" for adapter) and you will see output like:

    nmon v7a Hostname=host1 Refresh=2.0secs 16:51.37
    Adapter I/O read write xfers Disks Adapter Type
     fscsi0 1j-08-01 511.7 0.0 KB/s 16.0 21 FC SCSI I/O Controller Protocol Device
     fscsi1 14-08-01 495.7 0.0 KB/s 15.5 21 FC SCSI I/O Controller Protocol Device
           TOTALS 1009.4 0.0 KB/s 32.0 TOTAL= 1009.4

    More details are available in the "IBM ESS800 Perf and Monitor Guide":
    http://publib-b.boulder.ibm.com/Redbooks.nsf/RedpieceAbstracts/sg246422.html?Open

    -pablo

    ---
    Pablo Clifton
    UNIX Technical Services
    (904) 905-7113
    (904) 588-4399 cell
    -----Original Message-----
    From: IBM AIX Discussion List [mailto:aix-l@Princeton.EDU]On Behalf Of
    Jason delaFuente
    Sent: Wednesday, February 25, 2004 4:41 PM
    To: aix-l@Princeton.EDU
    Subject: Re: SAN Adapter Stats
    If you are using the McData EFC Manager you can see all of the traffic at the switch port level by clicking on the switch/director, then going to the performance tab.
    Jason de la Fuente
    >>> D.Ousterhout@LABSAFETY.COM 02/25/04 03:19PM >>>
    Is there any way to get throughput statistics on my fcs0 and fcs1
    adapters? This is on a P690 with both adapters attached to McData
    switches and then on to our ESS800.
    Thanks
    -Darryl
    Blue Cross Blue Shield of Florida, Inc., and its subsidiary and affiliate companies are not responsible for errors or omissions in this e-mail message. Any personal comments made in this e-mail do not reflect the views of Blue Cross Blue Shield of Florida, Inc.  The information contained in this document may be confidential and intended solely for the use of the individual or entity to whom it is addressed.  This document may contain material that is privileged or protected from disclosure under applicable law.  If you are not the intended recipient or the individual responsible for delivering to the intended recipient, please (1) be advised that any use, dissemination, forwarding, or copying of this document IS STRICTLY PROHIBITED; and (2) notify sender immediately by telephone and destroy the document. THANK YOU.
    

  • Next message: Jason delaFuente: "Re: SAN Adapter Stats"

    Relevant Pages

    • Re: vpath vs hdisk question
      ... I googled them and looked in IBM ... Subject: vpath vs hdisk question ... Adpt# Adapter Name State Mode Select Errors Paths ... please notify me immediately by a return ...
      (AIX-L)
    • Re: vpath vs hdisk question
      ... Adpt# Adapter Name State Mode Select Errors Paths ... hdisk2 Available 11-08-01 IBM FC 2105800 ... email in error please notify the system manager at mailadmin@bisys.com ... This e-mail, and any attachments there to, ...
      (AIX-L)
    • Re: vpath vs hdisk question
      ... adapter and the storage device/switches ... Subject: vpath vs hdisk question ... Looks like fcs1 only has 2 paths to the disk. ... hdisk2 Available 11-08-01 IBM FC 2105800 ...
      (AIX-L)
    • Re: W9xNT MCA Adapters - SPOCK-206
      ... tuned parameters to increase the quality of communication, SCSI-II commands ... 8EF8 IBM Expansion Unit SCSI Controller ... 8EFD IBM 7568 Industrial Computer SCSI Adapter ...
      (comp.sys.ibm.ps2.hardware)
    • Re: 5170 for a mere G
      ... IBM 3363 Optical Disk interface -- IBM 3363 Optical drive external ... IBM AT Serial / Parallel Adapter ... It had PC-DOS 4.01 with IBM LAN Support and IBM LAN program installed. ... The Fujitsu SCSI drives are near to indestructible, except you store them six feet deep under salt water. ...
      (comp.sys.ibm.ps2.hardware)