Re: Migrating to FastT

From: Pugliese, Edward (EPugliese_at_NYBOT.COM)
Date: 07/21/05

  • Next message: faisalq . (faisalq): "C for AIX 6 error"
    Date:         Thu, 21 Jul 2005 15:10:10 -0400
    To: aix-l@Princeton.EDU
    
    

    I believe that result is due to you missing a fileset for FC dual path
    support. I don't recall offhand which one. I will research and
    respond later unless someone else pops in first.
     

    -----Original Message-----
    From: IBM AIX Discussion List [mailto:aix-l@Princeton.EDU] On Behalf Of
    Drew T
    Sent: Thursday, July 21, 2005 2:33 PM
    To: aix-l@Princeton.EDU
    Subject: Migrating to FastT

    Hello all.

    We are migrating a few of our non-production AIX boxes to Fast-T. We
    have two adapters zoned to the Fast-T, for redundancy (fcs0 and fcs2).

    [atownsen @ uxsyblab1] /home/unixsa/atownsen >>lsdev -Cc adapter | grep
    fc
    fcs0 Available 41-08 FC Adapter (Fast-T)
    fcs1 Available 47-08 FC Adapter (to something else)
    fcs2 Available 4F-08 FC Adapter (Fast-T)

    When we ran cfgmgr, each disk showed up twice. There are only 12
    physical disks, and there is an exported volume group on them. As you
    can see, there are actually 24 disks in the available state, 12 for each
    adapter.

    If I had only one adapter, and saw only 12 disks, I would go ahead and
    import the vg. But I'm not sure in this case. (It's only lab). Should I
    go ahead and import them anyway?

    Thanks,

    Drew

    Here is the lsdev output for the disks:

    [atownsen @ uxsyblab1] /home/unixsa/atownsen >>lsdev -Cc disk hdisk0
    Available 4M-08-00-8,0 16 Bit LVD SCSI Disk Drive
    hdisk1 Available 4M-08-00-9,0 16 Bit LVD SCSI Disk Drive
    hdisk2 Available 41-08-02 1742 (700) Disk Array Device
    hdisk3 Available 41-08-02 1742 (700) Disk Array Device
    hdisk4 Available 41-08-02 1742 (700) Disk Array Device
    hdisk5 Available 41-08-02 1742 (700) Disk Array Device
    hdisk6 Available 41-08-02 1742 (700) Disk Array Device
    hdisk7 Available 41-08-02 1742 (700) Disk Array Device
    hdisk8 Available 41-08-02 1742 (700) Disk Array Device
    hdisk9 Available 41-08-02 1742 (700) Disk Array Device
    hdisk10 Available 41-08-02 1742 (700) Disk Array Device
    hdisk11 Available 41-08-02 1742 (700) Disk Array Device
    hdisk12 Available 41-08-02 1742 (700) Disk Array Device
    hdisk13 Available 41-08-02 1742 (700) Disk Array Device
    hdisk14 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk15 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk16 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk17 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk18 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk19 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk20 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk21 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk22 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk23 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk24 Available 4F-08-02 1742 (700) Disk Array Device
    hdisk25 Available 4F-08-02 1742 (700) Disk Array Device

    "This e-mail and any attachments may contain confidential and privileged information. Any dissemination or use of the information by a person other than the intended recipient is unauthorized and may be illegal. If you are not the intended recipient, please notify the sender immediately by return e-mail, delete this e-mail and destroy any copies. Although this e-mail and any attachments are believed to be free of any virus or other defect that might affect any computer system into which it is received and opened, it is the responsibility of the recipient to ensure that it is virus free and no responsibility is accepted by the Board of Trade of the City of New York, Inc. or the New York Clearing Corporation for any loss or damage arising in any way from its use. Thank you."
     


  • Next message: faisalq . (faisalq): "C for AIX 6 error"

    Relevant Pages

    • Re: SSA Adapter Performance
      ... We've just installed a new SSA adaptor (IBM SSA 160 SerialRAID ... Adapter) with 128mb DRAM and 32MB of fast-write cache. ... Sometimes putting just the jfslog of the VG on 2 mirrored disks helps ... AIX mirroring with the right intra-policy setup and hottest LV's ...
      (comp.unix.aix)
    • Migrating to FastT
      ... We are migrating a few of our non-production AIX boxes to Fast-T. ... are actually 24 disks in the available state, 12 for each adapter. ... hdisk0 Available 4M-08-00-8,0 16 Bit LVD SCSI Disk Drive ...
      (AIX-L)
    • Re: SSA, Fast Cache En-/Dis-abled on the same adapter/loop
      ... This adapter doesn't support the command you outline. ... take longer processing for all disks. ... The security of electronic mail sent through the Internet ... Such requests, orders or instructions will ...
      (AIX-L)
    • Re: Moving MPIO disks between paths
      ... Most of my disks have ended up one ... adapter. ... Does the HPMPIOdriver even support this? ... How to setup manual load balancing on AIX with an HP XP1024: ...
      (comp.unix.aix)
    • Strange SSA failure
      ... I had a problem with some SSA hardware yesterday. ... This contained four 9GB and four 4.5GB disks. ... Adapter microcode is the latest level. ... pdisks the diagnostics were taking a very long time - 10-15 minutes. ...
      (AIX-L)