Re: Migrating to FastT

From: Michael H. Martel (martelm_at_QUARK.VSC.EDU)
Date: 07/22/05

  • Next message: Drew T: "Re: Migrating to FastT"
    Date:         Fri, 22 Jul 2005 10:25:30 -0400
    To: aix-l@Princeton.EDU
    
    

    --On July 22, 2005 1:33:14 PM +0200 Soós Zoltán <soos.zoltan@gmail.com>
    wrote:

    > Hmmm, then check your SAN setup. How many FC switches/VSANs do you
    > have in this installation? Are you sure your SAN zones are set up
    > correctly? Zones/VSANs should be set up in a way that each FC adapter

    No I'm not sure they're setup right. :-) This is all new to me with the
    SAN.

    > in the AIX box should only see (be in the same zone/VSAN with) one
    > controller of the FAStT. FAStT drivers are limited to handle two paths
    > between the OS and the logical disk defined in the FAStT box. More
    > paths result in multiple hdisks. Also, post the output of "fget_config
    > -Av" (SMutils.aix.rte must be installed) so we can see better what may

    # fget_config -Av

    ---dar0---

    User array name = 'VSC_DS4300_1'
    dac0 ACTIVE dacNONE ACTIVE

    Disk DAC LUN Logical Drive
    utm 31
    hdisk2 dacNONE 0 colleague2

    ---dar1---

    User array name = 'VSC_DS4300_1'
    dac1 ACTIVE dacNONE ACTIVE

    Disk DAC LUN Logical Drive
    utm 31
    hdisk3 dac1 0 colleague2
    #

    For the complete diagram of what my configuration looks like.

    I've got two lpar's in my p570. Each of the lpar's has two hba's. Each hba
    is connected to a FC Switch. Each Switch is connected to one of the
    controllers on the 4300.

    lpar 1
            - hba1 connected to Switch 1
            - hba2 connected to Switch 2

    lpar 2
            - hba1 connected to Switch 1
            - hba2 connected to Switch 2

    Switch 1 -----> 4300 Controller 1

    Switch 2 -----> 4300 Controller 2

    Iniitally there were no Zones on the switches. The Switches btw are
    IBM_2005_H08's .

    I created two zones on each switch. Each zone has one HBA in it and the
    Controller for the 4300.

    Michael

    --
      --------------------------------o---------------------------------
       Michael H. Martel              | Systems Administrator
       michael.martel@vsc.edu         | Vermont State Colleges
       http://www.vsc.edu/~michael    | PH:802-241-2544 FX:802-241-3363
    

  • Next message: Drew T: "Re: Migrating to FastT"

    Relevant Pages

    • Re: 3-part 3-way Switch Circuit Design
      ... in three separate lighting zones so that the room can be lit according ... electrician brain around it. ... That would be a 3PDT switch. ...
      (alt.home.repair)
    • Re: 3-part 3-way Switch Circuit Design
      ... in three separate lighting zones so that the room can be lit according ... electrician brain around it. ... That would be a 3PDT switch. ...
      (alt.home.repair)
    • Re: 3-part 3-way Switch Circuit Design
      ... how to approach the lighting. ... in three separate lighting zones so that the room can be lit according ... In my switch box, I'd also like to have one master switch that turns ...
      (alt.home.repair)
    • Re: 3-part 3-way Switch Circuit Design
      ... in three separate lighting zones so that the room can be lit according ... Flipping the master again would turn ... That would be a 3PDT switch. ...
      (alt.home.repair)
    • Re: 3-part 3-way Switch Circuit Design
      ... that circuit work, and like I said to mm, I was sure I'd done a master ... in three separate lighting zones so that the room can be lit according ... In my switch box, I'd also like to have one master switch that turns ...
      (alt.home.repair)