Hi all:
I had the same case, but IBM did not tell that I need the KVM.
I had connect 2X P550, each with 2 LPAR & the HMC station to a switch
using HMC port at the P550. They connect to each other by DHCP where is
the HMC is the DHCP server.
..... Hope this will help :-)
Thanks & Regards
_______________________________________________
Ayman Rayyan
________________________________
From: IBM AIX Discussion List [mailto:aix-l@Princeton.EDU] On Behalf Of
Vincent D'Antonio
Sent: Thursday, September 15, 2005 7:47 PM
To: aix-l@Princeton.EDU
Subject: Re: HMC for P5
What I am being told is that I have 30 P5 servers to connect to one HMC
using a TF3 keyboard, mouse, and display rack mounted. Because of this
I need a KVM FC7316 with FC4202 cables.
I still don't see the need for this but IBM says it is a recommend
setup?
Thanks
Vince
On 9/15/05, BRUCE HARVEY <btharvey@mandtbank.com> wrote:
It does not use a KVM ... it uses a monitor, keyboard/mouse
(touchpad/button), since it is a graphical interface. No KVM, though it
could use it I suppose, and its monitor/keyboard/etc.
The connections are via private LAN (literally a switch or hub connected
to the different systems and the HMC), rather than the old P4 serial
connections. Serial ports on the target system are still unavailable,
however. Don't get that, but whatever.
Bruce
>>> "Vincent D'Antonio" <dantoniov@gmail.com> 09/15/05 11:20 AM >>>
Need your help,
I would like to start using an HMC to manage my P5 servers, with the
lastest code we can connect up to 48 servers non-P590/P595.
The question I have is that I see that it uses a KVM switch and can't
figure out why it needs one? I read though the redbook (alittle out of
date) but it doesn't talk about the KVM.
Anyone using an HMC for P5 can shed some light on this that would be
great.
Thanks in advance,
Vince
This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please notify the system manager. This message contains confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail.