Re: VIO Issue
- From: "Copper, Steve" <scopper@xxxxxxxxxxxxxxxxxx>
- Date: Mon, 10 Apr 2006 13:35:12 +0100
Figured out the fileset issue - if you use "lssw -hist" it will show the
complete line, all the filesets needed are at version 5.3.0.40 comitted with
5.3.0.41 applied.
Cheers
Steve
_____________________________________________
From: Copper, Steve
Sent: 10 April 2006 13:31
To: Aix-L (aix-l@xxxxxxxxxxxxx)
Subject: VIO Issue
Hi All,
I have a question about multipathing on the VIO servers which I hope
someone can help with. Basically I am trying to set up the scenario as per
the attached diagram which is from the redbook sg247940, Advanced Power
Virtualization on IBM System p5, Chapter 5, page 249.
The only difference to the diagram is that the DS4800 goes through 2 SAN
switches, one controller through each. Each fibre card on the VIO is zoned
to see only one of the controllers. I have created a host group on the
ds4800 which has the 2 fibre cards in and 12 disks assigned to the host
group. As per the diag ds4800 attached.
The issue I am having is that in this configuration, after I have done the
cfgdev on the VIO server, I am seeing 2 hdisks for the same disk (I have
checked the ieee_volname parm to be sure). In this case I have
hdisk0-hdisk28 inclusive. Hdisk0, hdisk1 and hdisk2 are the internal
disks. Not sure what hdisk3 and hdisk4 are doing here, they were present
even before I allocated and disks to the VIO. Then I have hdisk5-28 which
are the 24 paths to the 12 disks.
As per the diagram, it indicates that there should only be 1 hdisk for the
disk as the RDAC driver will have sorted out the dual path to present only
the one disk. This is the part that I am not seeing and am stuck on.
Earlier on in the chapter on page 245 there is a Note which says to use
the oem_setup_env command (which creates a root shell) for installing and
configuring the multi-path environment on the VIOs. What commands are used
in the above shell to achieve the configuration?
One other thing that I have noticed is that when listing the filesets
which are required for the RDAC there is no version number or description
associated with them, as below. Is this right? Or should there be that
info?
$ lssw | grep fc
devices.common.IBM.fc.hba-api
devices.common.IBM.fc.rte
devices.fcp.disk.array.diag
devices.fcp.disk.array.rte
devices.fcp.disk.rte 5.3.0.41 A F FC SCSI CD-ROM, Disk,
devices.fcp.tape.rte 5.3.0.41 A F FC SCSI Tape Device
Software
Ioslevel on the VIOs is 1.2.1.1-FP-7.2
Thanks in advance for your replies.
Regards
Steve Copper
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email
______________________________________________________________________
- Prev by Date: Re: bad power supply
- Next by Date: VIO Issue
- Previous by thread: bad power supply
- Next by thread: VIO Issue
- Index(es):
Relevant Pages
- Re: VIO Issue
... John Monahan ... VIO Issue ... ds4800 which has the 2 fibre cards
in and 12 disks assigned to the host ... This email has been scanned by the MessageLabs
Email Security System. ... (AIX-L) - Re: LPAR setup recommendation
... > with 4 cpus and six disks (2 scsi buses). ... Apparently
5.2 doesn't support the VIO ... any other LPAR ist just an VLPAR uncapped setup
(keep it simple in the ... (comp.unix.aix) - VIO Issue
... The only difference to the diagram is that the DS4800 goes through 2 SAN ...
Each fibre card on the VIO is zoned ... ds4800 which has the 2 fibre cards in and 12 disks
assigned to the host ... The issue I am having is that in this configuration, ...
(AIX-L) - Re: carving disk on the San or vio ?
... if you're the person who manages both VIO and DS do carve all the disks
... virtualization and not, but data should be preserved at all time. ... (comp.unix.aix) - Re: Redundant VIOS and disk mapping
... we try to add some new LUNs to both vios - no problem. ... Next step was to
map the new "disks" to a lpar with the mkvdev-command ... Try to map these disks from the
second vio to the lpar - its impossible, ... I have a "volume group" which contains both
vio servers' ... (comp.unix.aix)