Re: LED Error Code E301 on p43-150
- From: "Green, Simon" <Simon.Green@xxxxxxxxxxxxx>
- Date: Wed, 28 Jun 2006 18:24:36 +0200
The procedure goes on to say that if removing the memory modules doesn't
help you should move on to the system board and other components.
Taking a disk from one system and using it to boot another can work, but
isn't always simple. It should be OK with PCI hardware but expect to have
to change a few things and at the least run cfgmgr with the install CD
loaded.
I've only done it with an MCA SP2 node and that was a lot of trouble, (but
better than the alternative at the time, since I had some critical data that
wasn't backed up). I'm told PCI servers are much easier, and of course the
PSSP configuration added to my woes.
--
Simon Green
Altria ITSC Europe s.a.r.l.
AIX-L Archive at https://lists.princeton.edu/listserv/aix-l.html
New to AIX? http://publib-b.boulder.ibm.com/redbooks.nsf/portals/UNIX
N.B. Unsolicited email from vendors will not be appreciated.
Please post all follow-ups to the list.
-----Original Message-----
From: IBM AIX Discussion List [mailto:aix-l@xxxxxxxxxxxxx] On Behalf Of
Naylor, Jim
Sent: 28 June 2006 17:15
To: aix-l@xxxxxxxxxxxxx
Subject: Re: LED Error Code E301 on p43-150
Thanks Simon. This is the procedure I had the FE follow but it did not
correct the problem. There were only 2 simms in the system. They are going
to take another system to the site and try swapping in the new memory from
the new system. This system had only two disks for the rootvg mirrored.
Can I take the disk from the old system and put them in the new system and
boot it up? Is there some steps I need to do to make this work?
Thanks,
Jim Naylor
Unix/Storage Systems Administrator
Schnuck Markets, Inc.
* Direct (314) 994-4784
))( Cell (314) 691-0186
Fax (314) 994-4684
* E-Mail jnaylor@xxxxxxxxxxxx
-----Original Message-----
From: IBM AIX Discussion List [mailto:aix-l@xxxxxxxxxxxxx]On Behalf Of
Green, Simon
Sent: Wednesday, June 28, 2006 10:13 AM
To: aix-l@xxxxxxxxxxxxx
Subject: Re: LED Error Code E301 on p43-150
The 43P Service Guide is the only source of information on this. It
basically describes removing the memory modules in order to find the faulty
one.
There's no quick and easy way: you'll have to be methodical and you'll end
up booting the system lots of times, potentially.
In my copy of the manual, it's MAP1240 on page 2-12. Don't skimp on the
steps, or try to take shortcuts.
--
Simon Green
Altria ITSC Europe s.a.r.l.
AIX-L Archive at https://lists.princeton.edu/listserv/aix-l.html
New to AIX? http://publib-b.boulder.ibm.com/redbooks.nsf/portals/UNIX
N.B. Unsolicited email from vendors will not be appreciated.
Please post all follow-ups to the list.
-----Original Message-----
From: IBM AIX Discussion List [mailto:aix-l@xxxxxxxxxxxxx] On Behalf Of
Naylor, Jim
Sent: 28 June 2006 15:30
To: aix-l@xxxxxxxxxxxxx
Subject: LED Error Code E301 on p43-150
Hello Admins,
I look all over for this error code and found something about memory but it
referred only to E3xx. I tried pulling out one chip then replacing the one
left in with the one I pulled out but still get the same error on bootup. I
could not find any other reference to this LED code. Anyone have any other
suggestions?
Thanks,
Jim Naylor
Unix/Storage Systems Administrator
Schnuck Markets, Inc.
* Direct (314) 994-4784
))( Cell (314) 691-0186
Fax (314) 994-4684
* E-Mail jnaylor@xxxxxxxxxxxx
______________________________________________________________________
The information transmitted (including attachments) is covered by the
Electronic Communications Privacy Act, 18 U.S.C. 2510-2521, is intended only
for the person(s) or entity/entities to which it is addressed and may
contain confidential and/or privileged material. Any review,
retransmission, dissemination or other use of, or taking of any action in
reliance upon, this information by persons or entities other than the
intended recipient(s) is prohibited. If you received this in error, please
contact the sender and delete the material from any computer.
______________________________________________________________________
The information transmitted (including attachments) is covered by the
Electronic Communications Privacy Act, 18 U.S.C. 2510-2521, is intended only
for the person(s) or entity/entities to which it is addressed and may
contain confidential and/or privileged material. Any review,
retransmission, dissemination or other use of, or taking of any action in
reliance upon, this information by persons or entities other than the
intended recipient(s) is prohibited. If you received this in error, please
contact the sender and delete the material from any computer.
- Prev by Date: Re: LED Error Code E301 on p43-150
- Next by Date: Re: LED Error Code E301 on p43-150
- Previous by thread: Re: LED Error Code E301 on p43-150
- Next by thread: Re: LED Error Code E301 on p43-150
- Index(es):