Re: ssa adapter cache error



Take a look at SRN 42525 in the adapter user guide. (I'm looking at the
Advanced Serial RAID Adapters User's Guide and Maintenance Information.)


Simon Green

EDS
c/o Kraft Foods
St George's House
Cheltenham
Gl50 3AE

Phone: +44 1242 284318
Fax: +44 1242 284510

+ mailto:simon.green@xxxxxxx


This email contains information which is confidential and may be
privileged. Unless you are the intended addressee (or authorised to
receive for the addressee) you may not use, forward, copy or disclose to
anyone this email or any information contained in this email. If you
have received this email in error, please advise the sender by reply
email immediately and delete this email.

Electronic Data Systems Ltd
Registered Office:, Lansdowne House, Berkeley Square, London W1J 6ER
Registered in England no: 53419
VAT number: 432 99 5915




-----Original Message-----
From: IBM AIX Discussion List [mailto:aix-l@xxxxxxxxxxxxx] On
Behalf Of Mark Schlechte
Sent: 19 February 2007 04:14
To: aix-l@xxxxxxxxxxxxx
Subject: ssa adapter cache error


I'm not entirely sure what happened here or what's going to
be the least painful remedy but we had an SSA adapter (6230 I
think) that was saying the battery needed to be replaced(
SSA_CACHE_BATTERY). My co-worker got a battery and what I
think is the fast rw/cache that goes with it?
I've replaced batteries before with no problems but this time
it came enclosed in what I think is the 32MB fast write cache.
At any rate, down the server and swap out the battery and
cache since it was easier than unclipping just the battery
but at bootup the VG is now unaccessible due to a wrong_cache error.
18:root:/bin/scripts > ssaraid -I -z -l ssa0
pdisk0 0040AA1DF9B200D member n/a
18.2GB Physical disk
pdisk1 0040AA81E38C00D member n/a
18.2GB Physical disk
pdisk2 0040AABD596100D member n/a
18.2GB Physical disk
pdisk3 00609481F80800D member n/a
18.2GB Physical disk
pdisk4 00609481FA2F00D member n/a
18.2GB Physical disk
pdisk5 006094A610D500D member n/a
18.2GB Physical disk
pdisk6 006094A676D500D member n/a
18.2GB Physical disk
pdisk7 006094A676E800D member n/a
18.2GB Physical disk
pdisk8 006094BE51D200D member n/a
18.2GB Physical disk
pdisk9 0090D613B06300D member n/a
18.2GB Physical disk
pdisk10 0090D65437F200D member n/a
18.2GB Physical disk
pdisk11 0090D657269F00D member n/a
18.2GB Physical disk
pdisk12 0090D693DA7E00D member n/a
18.2GB Physical disk
pdisk13 0090D695589F00D member n/a
18.2GB Physical disk
pdisk14 0090D69558A600D member n/a
18.2GB Physical disk
pdisk15 0090D696D86900D member n/a
18.2GB Physical disk
hdisk2 F41F43ECA5FB4CK wrong_cache
127.6GB RAID-5 array
hdisk3 F41F43ECA6254CK wrong_cache
127.6GB RAID-5 array

So I can't varyon the vg anymore etc.
Anybody ever see this error before?
Any suggestions? This is a test server so I can just blow
away the array, rebuild and restore if needed.
I wasn't actually working on this but it should now be back
to it's original config with old battery and module.



Relevant Pages

  • Re: ssa adapter cache error
    ... City of Regina - Information Systems ... be the least painful remedy but we had an SSA adapter (6230 I ... My co-worker got a battery and what I ... 18.2GB Physical disk ...
    (AIX-L)
  • Re: ssa adapter cache error
    ... Take a look at SRN 42525 in the adapter user guide. ... be the least painful remedy but we had an SSA adapter (6230 I ... My co-worker got a battery and what I ... 18.2GB Physical disk ...
    (AIX-L)