Re: Power-Mgt (Was: Re: cvs commit: src/sys/i386/cpufreq est.c )



On Tue, 18 Mar 2008 19:59:40 -0000 "Poul-Henning Kamp" <phk@xxxxxxxxxxxxxx> wrote:
In message <20080318185435.GA2853@xxxxxxxxxxxxxxxxxxxxxx>, Brooks Davis write
s:

For amusement value, I had a dual P4-Xeon box hooked up to one once
and found that power consumption with SETI@Home running was about 10W
_lower_ than idle.

That is a very good indication that the meter is a piece of crap that
does not have sufficient measurement rate to do a relevant job.

You are likely right but it is also possible the system is
poorly designed or broken in some way and does in fact draw
more power when idle. Brooks ought to hook up his particular
p4-xeon box to another brand meter to verify.

Unfortunately, that is the case for most of the gadgets you can buy
in shops.

In general, you are much better off buying the real thing, for instance
a single-phase DIN power-meter like:

http://www.metermaid.co.uk/din_rail_tech_info.html

They cost less than EUR100/USD150 and have 1% accuracy.

The "SO" output can be hooked up to a parallel or serial port and
you can accumulate and read the number of pulses using the PPS-API,
giving you, in this case, 500mWh resolution.

I have been pretty happy with the Wattsup Pro meter but I
admit I have not calibrated with to any known good reference
for computer loads. It does a pretty accurate job on
constant loads (verified with a DMM with good AC amps
capability). It measures power down to a watt or so, with
100mWh resolution. Very useful for measuring standby mode
power use (chargers, computer, laser printer, TV, phone, etc.
-- can easily add up to over a Megawatt-hour a year!). I
have the older serial only meter but now it comes with a USB
port (about $130)

https://www.doubleed.com/secure/products.php
_______________________________________________
freebsd-arch@xxxxxxxxxxx mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-arch
To unsubscribe, send any mail to "freebsd-arch-unsubscribe@xxxxxxxxxxx"



Relevant Pages

  • Never bitch you have no bench supply.....
    ... Commercial high-voltage power supplies are few and far between, ... low voltage drop across them, lower than the big pass tube triodes. ... It's perfect for this use because it has a lot of windings, ... The meter movement is a standard 50 microamp full-scale meter. ...
    (rec.audio.tubes)
  • Re: Digital meter feedback?
    ... It requires a 5VDC power supply. ... I am using the meter with a 13.8V system. ... Without the shunt leads ... As soon as the shunt leads are ...
    (sci.electronics.basics)
  • Re: Digital Elec. meter - is this a problem?
    ... reside in Clearwater FL, 1 month ago local power co, ... swapped out our old electric meter on house to new honeywell digital - ... signals for meter readings. ... I'd ask to see the data when they come to retrieve the recorders. ...
    (misc.consumers.house)
  • Re: Yet another power outage.
    ... I was listening as the power went down, and like I expected the S3 ... The wire antenna wasn't as good as the roof mounted ... I could hear the noise increase but even with power on the ... He had already had to replace the wires to the meter after ...
    (rec.radio.shortwave)
  • Re: Yet another power outage.
    ... The wire antenna wasn't as good as the roof mounted ... I could hear the noise increase but even with power on the ... He had already had to replace the wires to the meter after ...
    (rec.radio.shortwave)