Disk I/O Performance with CCD

From: Kristofer Pettijohn (krishopper_at_cybernetik.net)
Date: 10/19/04

  • Next message: Joćo Assad: "Re: problem configuring ipfilter for multiple network routing"
    Date: Tue, 19 Oct 2004 14:22:52 -0500
    To: freebsd-isp@freebsd.org
    
    

    Im looking for some suggestions on I/O performance.

    I'm using FreeBSD 4.10-RELEASE on a Usenet transit server running
    Diablo for the transit software.

    I have 4 Seagate ST373435LC SCSI drives, 70GB each, and I am using
    CCD to bind them together with RAID-0 stripes.

    I can pull in anywhere from 30-40 MB sec and push out ~ 8-15 MB/sec..
    averaging about 50 MB/sec throughput.. feeds coming in are coming
    in just fine, but sending stuff back out is lagging behind.. its
    falling about a half hour behind every hour.

    I've used tunefs to set the average file size to 20 MB and enabled
    soft-updates, as these are generally larger binary files that just
    get appended to, and then seeked later on to send the article out,
    I've played with setting the stripe size from anywhere between 8MB
    and 64MB, and did not see much change on performance between those.

    Maybe I'm just missing something small, but on these SCSI drives
    which have 160 MB/s transfer rates, I'm expecting a bit more than
    I'm getting with CCD.

    Can someone give me any pointers to look at or suggestions of things
    to try?

    Thanks!

    Kristofer
    _______________________________________________
    freebsd-isp@freebsd.org mailing list
    http://lists.freebsd.org/mailman/listinfo/freebsd-isp
    To unsubscribe, send any mail to "freebsd-isp-unsubscribe@freebsd.org"


  • Next message: Joćo Assad: "Re: problem configuring ipfilter for multiple network routing"

    Relevant Pages

    • Disk I/O Performance
      ... Im looking for some suggestions on I/O performance. ... I'm using FreeBSD 4.10-RELEASE on a Usenet transit server running ... CCD to bind them together with RAID-0 stripes. ... I've used tunefs to set the average file size to 20 MB and enabled ...
      (freebsd-performance)
    • Disk I/O Perforamnce with CCD
      ... Im looking for some suggestions on I/O performance. ... I'm using FreeBSD 4.10-RELEASE on a Usenet transit server running ... CCD to bind them together with RAID-0 stripes. ... I've used tunefs to set the average file size to 20 MB and enabled ...
      (freebsd-questions)
    • Re: Disk I/O Performance
      ... The manual for vinum recommends avoiding chunk sized to a ... > I'm using FreeBSD 4.10-RELEASE on a Usenet transit server running ... > CCD to bind them together with RAID-0 stripes. ...
      (freebsd-performance)