Re: 3ware raid

From: Carroll Kong (me_at_carrollkong.com)
Date: 10/27/04

  • Next message: Mikhail P.: "question on vinum"
    To: <freebsd-stable@freebsd.org>
    Date: Tue, 26 Oct 2004 18:40:29 -0400
    
    

    Well, in the normal cases (where the disk is legimately dying) you can
    usually replace it and be okay. (recalling one instance from the massive
    thread regarding a 3ware 7506 with maxtor disks that had issues but once
    they replaced bad disks they were a-ok).

    You can use smartmontools to help you run tests on the hdds under a 3Ware
    controller while still in FreeBSD. It works in 4.X (with the latest
    snapshot of smartmontools).

    In the other cases where the disk appears fine, but still randomly pulls
    disks into DEGRADED mode, you have to find out why.

    In some cases it's because the power drop is too significant, which means
    you need to swap out your power supply. In other cases, the IDE cabling is
    legitimately bad (in my case, I highly suspect it is the IDE backplane,
    which is part of the disk-to-controller data path so I put bad cabling in
    quotes there). In short, 3Ware makes a note that you must ensure the entire
    data path is squeaky super clean. Of course, the problem could be the
    controller itself...

    3Ware claims it takes a lot of punishment to DEGRADE the disks. There are
    some procedures to pull out the extended diagnostics from 3Ware controllers
    via the 3ware command line utility and if you send them to 3Ware they can
    try to tell you more information.

    In my case, 3Ware copped out and gave me some BS excuse for why my system
    had issues.

    - Carroll Kong
    ----- Original Message -----
    From: "Marc G. Fournier" <scrappy@hub.org>
    To: "Carroll Kong" <me@carrollkong.com>
    Cc: <freebsd-stable@freebsd.org>
    Sent: Tuesday, October 26, 2004 6:27 PM
    Subject: Re: 3ware raid

    > On Tue, 26 Oct 2004, Carroll Kong wrote:
    >
    > > 4) Monitor the system carefully. Apparently in DEGRADED mode, the
    > > system has a high chance of complete lockups if left unattended. It is
    > > important to note that the 3Ware controller is very sensitive. People
    > > have gone into DEGRADED mode randomly because of slight power drops or
    > > "bad" IDE cabling.
    >
    > How do you test (and fix) something like this? revive the drive and hope
    > the same drive doesn't happen again?
    >
    >
    > ----
    > Marc G. Fournier Hub.Org Networking Services
    (http://www.hub.org)
    > Email: scrappy@hub.org Yahoo!: yscrappy ICQ:
    7615664
    >

    _______________________________________________
    freebsd-stable@freebsd.org mailing list
    http://lists.freebsd.org/mailman/listinfo/freebsd-stable
    To unsubscribe, send any mail to "freebsd-stable-unsubscribe@freebsd.org"


  • Next message: Mikhail P.: "question on vinum"

    Relevant Pages

    • FS: Lots of Digital Alphaservers and related equipment
      ... Dual power supply ... x SAS FDDI ...
      (comp.sys.dec)
    • Re: A sorry saga
      ... May we assume you have the XFC cache going? ... Within hours, however, we were seeing disk and file corruption - I cleaned ... corruption when the power had gone. ... We then scrounged some disks & cradles for inside the ds20e, ...
      (comp.os.vms)
    • RE: Aborted commands with arcmsr and 2xWD1500ADFD in RAID1
      ... Aborted commands with arcmsr and 2xWD1500ADFD in RAID1 ... Putting the disks in anti-vibration mounts in 5.25" slots. ... Using legacy ATA power connectors instead of the SATA ones. ... > The vibration could be caused by FANs not only by themselves. ...
      (Linux-Kernel)
    • Re: Power saving/spinning down RAID drives
      ... If you don't use the server it will take up memory (I have turned off ... > get some power savings for nothing that would be nice. ... And then there are the disks. ... That entails turning off swap, natch, and going noatime, and so on. ...
      (comp.os.linux.misc)
    • Re: Power saving/spinning down RAID drives
      ... If you don't use the server it will take up memory (I have turned off ... > get some power savings for nothing that would be nice. ... And then there are the disks. ... That entails turning off swap, natch, and going noatime, and so on. ...
      (comp.os.linux.hardware)