Re: question on vinum

From: secmgr (security_at_jim-liesl.org)
Date: 10/27/04

  • Next message: Peter Ulrich Kruppa: "RE: ppp -nat broken???"
    Date: Wed, 27 Oct 2004 08:57:40 -0600
    
    

    Chuck Swiger wrote:

    > No. All of the drives need to be the same size. With RAID-5, which
    > drive is used to hold parity data rotates on a stripe-by-stripe basis
    > to balance out the load.

    Just to clarify this point. All the subdisks in the plex need to be the
    same size. The physical drives and even the bsd partitions/vinum drives
    do not actually have to be the same.

    An example would be you have 2x 40gig partitions, and 2x 60 gig
    partitions. You could make a stripe set using 4 40gig (160gig) subdisks
    (or a 120gig raid 5 set). You just would't use the remaining 20 gig on
    the other two drives. You could use the space, just not for this plex.
    (you could create a 40gig (20+20) stripe or concat set or a mirrored
    20gig area) Concat, on the other hand doesn't care and would happily use
    40+40+60+60 (just not with the same perf levels)

    jim
    _______________________________________________
    freebsd-stable@freebsd.org mailing list
    http://lists.freebsd.org/mailman/listinfo/freebsd-stable
    To unsubscribe, send any mail to "freebsd-stable-unsubscribe@freebsd.org"


  • Next message: Peter Ulrich Kruppa: "RE: ppp -nat broken???"

    Relevant Pages

    • Re: RAID, Vinum and different disksizes
      ... Every time I think I have understand some of the vinum man page, ... you could make two VINUM subdisks on one drive. ... subdisk to an existing concat plex, or make a new volume that uses it. ... drives to provide a mirrored volume for /home. ...
      (freebsd-questions)
    • Vinum Offset for Swap: 265 or 281?
      ... The mirrored drives are ad4s1 and ad8s1. ... plex org concat ... sd len 2097152s driveoffset 4194288s drive rootmirrordev ...
      (freebsd-questions)
    • vinum striped volume has corrupt plex, help needed
      ... It's composed of 5 scsi drives of 4G each. ... the plex was corrupt and one of the subdisks was stale (see "vinum list" ... sd name striped.p0.s1 drive b len 8189588s driveoffset 265s state stale plex ... striped.p0 plexoffset 746s ...
      (freebsd-questions)
    • Re: Failure of gvinum after panic
      ... plex name data01.p0 org concat vol data01 ... sd name usr.p0.s0 drive donau len 11521427s driveoffset 4505865s ...
      (freebsd-stable)
    • Re: Vinum: How to safely remove a volume/drive from the configuration
      ... the full output of 'vinum l' below as it shows up now, ... plex name test.p0 org concat vol test ...
      (freebsd-questions)