Re: mpt problems. (Re: Dell hardware raid 0 (sas5ir) or gmirror?)



On Sat, Jan 27, 2007 at 10:47:49PM +0000, Josef Karthauser wrote:

The error messages from mpt are attached in the file called 'messages'.
The kernel probe boot time log is attached as dmesg.log.


Jan 27 18:42:03 littoralis kernel: mpt0: QUEUE FULL EVENT: Bus 0x00 Target 0x01 Depth 121
Jan 27 18:44:01 littoralis kernel: mpt0: QUEUE FULL EVENT: Bus 0x00 Target 0x00 Depth 121
Jan 27 18:51:06 littoralis kernel: mpt0: request 0xca756328:48785 timed out for ccb 0xca8f0c00 (req->ccb 0xca8f0c00)
Jan 27 18:51:06 littoralis kernel: mpt0: attempting to abort req 0xca756328:48785 function 0
Jan 27 18:51:06 littoralis kernel: mpt0: request 0xca755c28:48786 timed out for ccb 0xcc213800 (req->ccb 0xcc213800)

An update for anyone who's following this thread.

At Matthew Jacob's suggestion I tweaked the 'camcontrol tags'
settings for the drives, and with a particular choice of settings
the problems goes away.

So, at boot time both drives (da0|1) report that they have 255 tag
openings. However you can see above in the logs that the mpt files
when the depth gets to 121. If I manually set the tags for the
drives to anything 120 or above the drive controller complains under
load, and one of the disks goes away. If I get it to 119 the server
runs all day without missing a beat.

Matt suggested quirking the drives to fix this. I'm wondering though
where it is that the mpt controller get the queue size of 121 from, and
why the drives report 255 at boot time. Is this because the control
isn't mediating this information properly, or is there a bug in the
controller firmware or driver?

Joe

Attachment: pgpmYJ9s3GxG1.pgp
Description: PGP signature



Relevant Pages

  • Re: Looking for SAS/SATA RAID Controller That Supports JBOD
    ... Right, which is why one speaks of a JBOD cabinet, not a JBOD drive. ... All refer to such a controller as a *RAID* controller supporting JBOD ar- ... -or- an external controller spanning drives in a cabinet. ...
    (comp.periphs.scsi)
  • Re: 3B2 Disks
    ... being able to read the disk in its present format. ... 2 MFM drives on a custom controller. ... SCSI came much later as an add on card. ...
    (comp.sys.3b1)
  • Re: How to play an old floppy disk.
    ... Here are the circuit diagrams for the FDD/HDD controller in the ... Therefore it has the same data rate and should be ... Are you sure there ever were drives for 40 tracks double sided? ... Specifies the size of the floppy disk to format. ...
    (comp.sys.ibm.pc.hardware.storage)
  • Re: 3B2 Disks
    ... 2 MFM drives on a custom controller. ... what it came out of) but the only SCSI I heard about on the 3B's used ... any software out and would more likely have recycled the floppy disks. ...
    (comp.sys.3b1)
  • Re: Model 4 Disk Drive Issue
    ... controller command could be changed to one that does write. ... remove media from all other drives. ... (If you have Tandon drives you will need to change the step rate*. ... each group is content of the floppy disk controller status register. ...
    (comp.sys.tandy)