Re: A little story of failed raid5 (3ware 8000 series)



David Schwartz wrote:
A day ago at 11 am i have turn off the server,
pull out the old driver, installed a new one, turned of the server
and started rebuild in an hour from remote location via web
interface. After about 5 minuted the machine became unresponsive.
Tried rebooting - nothing. I went to the machine and fingure out,
that rebuild failed (0%) and some data cannot be read because of bad
sectors.

Why would you power cycle a RAID 5 array with a failed drive? That's
like the biggest no-no that there is. When you lose a drive on a RAID
5 array, you are vulnerable until a replacement drive is configured
and the array is rebuilt. Any high risk operations during that time
would be foolhardy.

Um.. it is because i did not have a map of hot swap baskets to conroller
ports and i needed to check every driver basket to understand which port
it sits on. I have no choise, i think.


So, no raid5 or even raid 6 for me any more. Never!

Since RAID6 would have saved you from what presumably was a drive
failure before a rebuild could be done, it's hard to understand why
you would say this is a reason to avoid RAID 6. Perhaps you would do
better to understand your failure and avoid the causes of the failure
rather than avoiding the things you happened to be using at the time
of the failure.

If you get food poisoning while wearing a blue shirt, the solution is
not to avoid blue shirts in the future.

Read the post before. I still don't known which driver has the bad sectors.
And it is very posible that EACH driver has them. RAID6 would not help then.

--
Artem
_______________________________________________
freebsd-stable@xxxxxxxxxxx mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-stable
To unsubscribe, send any mail to "freebsd-stable-unsubscribe@xxxxxxxxxxx"



Relevant Pages

  • RE: A little story of failed raid5 (3ware 8000 series)
    ... and started rebuild in an hour from remote location via web interface. ... Why would you power cycle a RAID 5 array with a failed drive? ... Since RAID6 would have saved you from what presumably was a drive failure ... this is a reason to avoid RAID 6. ...
    (freebsd-stable)
  • Re: trouble HP SmartArray 6400
    ... A "Predictive Failure", but I don't know what is this. ... (google punctured strip). ... You did not say if you replaced pd4 or not. ... raid, rebuild the raid, restore the data. ...
    (Debian-User)
  • Re: trouble HP SmartArray 6400
    ... A "Predictive Failure", but I don't know what is this. ... (google punctured strip). ... You did not say if you replaced pd4 or not. ... raid, rebuild the raid, restore the data. ...
    (Debian-User)
  • Re: HELP Network problem
    ... I rebooted and the system came back up but didnt find a network connection. ... As expected as I had to rebuild the driver for my card. ... However rebuilding the driver and inserting it didnt work. ...
    (Debian-User)
  • A little story of failed raid5 (3ware 8000 series)
    ... bigger driver and setup two mirrors instead. ... and started rebuild in an hour from remote location via web interface. ... Maybe i could tell teh controller to ignore all the ... It seems a lot more safe, since if any pair of disks failed the data is still readable and even if all disks have bad block the data can be easily recovered by fairly simply script from the couterpart. ...
    (freebsd-stable)