E3500 - Bad Disk ?

From: David Price (dprice_at_plugnpay.com)
Date: 05/08/03

  • Next message: Anshuman Kanwar: "280R with additional qlogic HBA"
    To: <sunmanagers@sunmanagers.org>
    Date: Thu, 8 May 2003 17:43:00 -0400
    
    

    I am running the E3500 with 2 internal FCAL drives. 1 drive is slot 0 and a
    mirror in slot 4.
    Mirror is managed by Volume Manager. System is running 2.6

    Complete history of the last month or so is as follows:

    System crashed.
    On reboot system complained that boot drive was bad. System and Drives are
    approx. 4 years old.
    Not knowing any better I, and not knowing how to boot off the mirror, I
    removed the drive and placed the mirror in its place.

    System them booted.

    2 Replacement drives were purchased. With assistance from Veritas we were
    able to put one of the new drives in the mirror slot (slot 4) and rebuild
    the mirror.

    Jump ahead 4 weeks.

    System would not come up during a reboot complaining initially that the
    drive had an invalid root plex and then subsequently that the drive was
    offline.

    Machine was then booted successfully off the mirror. Drive was flagged for
    removal and then removed. A replacement drive was inserted and system was
    rebooted after a 'touch /reconfigure' but drive can not be seen by system.
    System complains that bus is offline.

    At this point I suspect either the GBIC, Fiber Cable or the replacement
    drive is bad. The replacement drive is most likely a refurbished drive even
    though this was not stated at time of purchase. So it not unlikely that the
    drive could be bad from the start.

    The system has 2 I/O cards installed with 1 card going to the lower bus and
    the 2nd card going to the upper bus.

    I noticed that each IO card has slots for 2 GBIC's but only 1 is used. Also
    the FCAL interface board also has 2 GBIC slots for each bus but only 1 per
    bus is being used.

    Would connecting all 4 GBIC's provide greater redundancy/fault tolerance ?

    Does anyone know of a history of a Fiber Cable going bad over time ?

    Are the GBIC's and Cable hot swappable ?

    Thoughts and recommendations appreciated

    I will summarize.

    Thanks

    Dave
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Anshuman Kanwar: "280R with additional qlogic HBA"

    Relevant Pages

    • Re: Worst monday of my life - please help...
      ... If that's the case, restoring the SQL ... but it finally did install with a few hiccups. ... >> or just leave the mirrored drives in the server on the secondary IDE ... I decided it was time to re-add the mirror. ...
      (microsoft.public.windows.server.sbs)
    • Re: Realistic drive arrays
      ... > may be an opportunity to swap 2 of the disks for a pair of 143Gb drives ... >> two drives in the same mirror failing within the parts replacement SLA of ... >> How much memory the store.exe process uses really depends on how much ... >>> copy of the database on the disk. ...
      (microsoft.public.exchange.setup)
    • Re: Mirroring help
      ... not to use the OS disk mirror since it only uses up precious processor time ... The better solution is to use SCSI hard drives and to do the RAID ... could mirror a partition on a hard drive to free space on the same drive, ...
      (microsoft.public.backoffice.smallbiz)
    • Re: hardware for Exchange 2003
      ... your current server will work fine. ... in daily bases or weekly bases in order to commit the T.L files into Exchange ... one(or mirror or RAID 1) for Transaction Log files and let's call this D: ... ALL SCSI drives running at 15krpm for maximum throughput. ...
      (microsoft.public.exchange.design)
    • Re: Worst monday of my life - please help...
      ... Also If your mirror was broke did you see anything in logs to indicate why? ... > I have a customer who had a Windows 2000 Small Business Server running ... but it finally did install with a few hiccups. ... > or just leave the mirrored drives in the server on the secondary IDE ...
      (microsoft.public.windows.server.sbs)