Formatting of LUN taking a *very* long time in RM6

From: Adam Mazza (adam_at_68e.com)
Date: 10/29/03

  • Next message: gangadharan.manikandan_at_polaris.co.in: "SCSI reset errors"
    Date: Tue, 28 Oct 2003 23:58:25 -0500 (EST)
    To: sunmanagers@sunmanagers.org
    
    

    Hello,

    I have an A1000 that has a four disk RAID0 LUN. (mirrored in SW to another
    A1000) One of the disks in that LUN died and a new disk was hot swapped
    in. The recovery utility has been going for a bit over 3 hours already and
    is in the "Formatting" state. The drives in the lun are 36gig drives. Is
    this the normal amount of time it should take? The light on the front did
    turn green again, and blinks along with the other drives in the LUN about
    once every 10 seconds. The one thing I did notice is that the drive that
    was swapped in, even though it was the exact same model number, is Sun
    formatted, shows a different firmware revision, and because of that ends
    of being about a meg smaller. I'm using VxVM to mirror so this size
    different shouldn't really matter.

    Thanks

    Adam Mazza
    PGP Key:http://pgp.mit.edu:11371/pks/lookup?op=get&search=0x382775D1
    Key fingerprint = 5A82 FA7F 459C E805 6C00 3211 48AC 6069 3827 75D1
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: gangadharan.manikandan_at_polaris.co.in: "SCSI reset errors"

    Relevant Pages

    • Re: expand database volume
      ... disk perforance counters circa Windows NT and 2000. ... could create a new R5 with the larger drives and attach that to the lun. ... more disks to our SAN. ...
      (microsoft.public.exchange.admin)
    • Re: expand database volume
      ... disk perforance counters circa Windows NT and 2000. ... could create a new R5 with the larger drives and attach that to the lun. ... more disks to our SAN. ...
      (microsoft.public.exchange.admin)
    • Veritas disk replacement problems (A1000)
      ... Two A1000 disk arrays with four disks in each. ... A drive in LUN 1 started getting r/w errors and then RAID Manager ... Ran vxdctl enable, vxdisk list ... error that there were no available drives to use as replacement. ...
      (comp.unix.solaris)
    • Re: possible hdd failure?
      ... > I could no longer boot into windows in either safe mode or normal mode. ... > (XP boot disks don't allow you to see drives XP created?), ... > formatting the hard drive, I tried booting from the XP CD to run the ...
      (microsoft.public.windowsxp.general)
    • Re: SAN Drive Presentation
      ... Since the LUN order on Node2 is what it should be, ... Unpresent the drives to Node1 ... Rejoin Node1 to the cluster. ... physical disks from the cluster, remove the disks from device manager, ...
      (microsoft.public.windows.server.clustering)