A1000/RM6 refuses to create new LUN

From: Bryan Guest, BMI Internet (bryan.guest_at_bmts.com)
Date: 10/29/03

  • Next message: Birl: "(long) bsmconv / auditing questions"
    To: <sunmanagers@sunmanagers.org>
    Date: Wed, 29 Oct 2003 13:08:24 -0500
    
    

    Hello:

    I have an E420R/Solaris 8 hooked to an A1000 disk array.

    Originally I had only 5 18Gb disks in the A1000 due to budgeting issues.
    I created LUN 0 / Drive Group 1 over 4 of the 5 disks, and left 1 disk for a
    hot spare.

    Now I have filled the remaining 7 disks to take the A1000 to 12x18Gb.

    Unfortunately RaidManager 6 does not permit the growing of LUNS. So I want
    to make a new LUN / Drive Group out of the new disks.

    I select the unassigned disks and choose the create LUN option. RM6 permits
    this. It allows me to select the available disks, and it appears to start
    to create the LUN. (LUN 1, Raid 5, 103408Mb)

    Then it comes back and says that it failed to create the LUN for one of the
    following reasons:

    Failed to create the following LUNS on Module_001:LUN 1

    1 Another host has created LUNS or hot spares on the module using the same
    drives or LUN numbers.
    2 A LUN or group is being modified
    3 A failure has occured along the connection.

    Of course this is all rubbish.

    1. This is the only host connected. The other LUN is LUN0 on the other 5
    drives.
    2. I am the only one logged into the box, and therefore no other LUN
    changes are happening
    3. The other LUN is operating fine. There are no warnings in the Recovery
    Guru.

    On the console I see this error:

      No disks found!

    Even though I have 7 shiny new disks I want to use.

    So has anyone seen this before or can someone point me in the right
    direction to a solution?

    Thanks
    Bryan Guest
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Birl: "(long) bsmconv / auditing questions"

    Relevant Pages

    • Veritas disk replacement problems (A1000)
      ... Two A1000 disk arrays with four disks in each. ... A drive in LUN 1 started getting r/w errors and then RAID Manager ... Ran vxdctl enable, vxdisk list ... error that there were no available drives to use as replacement. ...
      (comp.unix.solaris)
    • Re: Sizing Exchange Transaction, SMTP, MTA and Quorum Drives???
      ... Put the transaction logs for each storage group on their own drive (4 ... storage groups 4 drives). ... Make sure you add in IOPS ... But assigning 1460 GB for each LUN using traditional Storage methods leads ...
      (microsoft.public.exchange.design)
    • Re: SAN Drive Presentation
      ... Since the LUN order on Node2 is what it should be, ... Unpresent the drives to Node1 ... Rejoin Node1 to the cluster. ... physical disks from the cluster, remove the disks from device manager, ...
      (microsoft.public.windows.server.clustering)
    • Re: Smartarray 5300 & hot spare
      ... is assigned as a hot spare to all three arrays. ... Unit 0 is Lun 0. ... Spare physical drives: ... It's one spare disk per LUN and one LUN ...
      (comp.os.vms)
    • Re: Smartarray 5300 & hot spare
      ... Unit 0 is Lun 0. ... Volume status    : VOLUME failed ... Spare physical drives: ...
      (comp.os.vms)