SUMMARY: E450 - best database disk layout

egold_at_fsa.com
Date: 11/26/03

  • Next message: Janik, Jesse: "ire_init: no dlureq_mp"
    To: sunmanagers@sunmanagers.org
    Date: Wed, 26 Nov 2003 12:58:46 -0500
    
    

    Most all agreed to use a 2 disk mirror instead of a 3 disk raid5 for a
    database,
    thanks gurus!

    egold@fsa.com wrote:
    >
    > I have an E450 running informix,
    > it has 2 extra internal disks and
    > an external S1 array with 3 disks as a raid5
    >
    > would it be faster to put informix on the 2 internal disks as a mirror or
    > on the 3 external disks as a raid5 ?
    >
    > thanks gurus!
    > _______________________________________________
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Janik, Jesse: "ire_init: no dlureq_mp"

    Relevant Pages

    • Mirror status
      ... Is there a way to programmatically get Disk Mirror status from the Logical ... Disk Manager? ... I have noticed that in WMI class Win32_LogicalDisk most of the information ...
      (microsoft.public.windows.server.scripting)
    • Re: Vinum + new disk for mirror
      ... Just a follow up on my recent vinum disk replacement question... ... I have a two disk mirror and one of the disks died; ... - edit the partition table with disklabel to match the ...
      (freebsd-questions)
    • Migrating Veritas logical volumes config to another internal disk
      ... We have a E45K with two internal disks. ... internal disks are mirrored with veritas but the file ... We have three disk arrays connected in daisy chain to ...
      (SunManagers)
    • [HPADM] RE: SCSI: Read error
      ... The concerned disk is the 2nd internal disk c2t2d0 ... $ ioscan -kfnC disk ... Is there an equivalent command on HP-UX? ... This HP server has 2 internal disks and a EMC disk array attached to it. ...
      (HP-UX-Admin)
    • [HPADM] SUMMARY: SCSI: Read error
      ... 2/ Address 0x022000, indicates disk c2t2d0 ... stopped responding to SCSI commands ... Before concluding the disk is nearly dead, I'm going to apply LVM and SCSI ... This HP server has 2 internal disks and a EMC disk array attached to it. ...