Disksuite Problem

From: David Price (dprice_at_plugnpay.com)
Date: 12/09/03

  • Next message: Alan Bird: "Netra T1 100 & 105"
    To: <sunmanagers@sunmanagers.org>
    Date: Tue, 9 Dec 2003 16:34:37 -0500
    
    

    System is a V120
    Solaris 8
    We recently used DiskSuite to Mirror the boot drive.
    We are getting Read Errors on the boot drive so we are trying to replace it.
    We can boot off the mirror but when we swap the primary drive and reboot it
    won't get past the OK prompt.
    I unfortunately don't have the exact error message for this problem.
    Possible related, running metastat produces the results below. Only the
    parts indicating an error are shown.

    Going with the theory that I should tackle one problem at a time, can anyone
    tell me how to repair the condition as shown below.

    I am unsure as to which command I should run first. Should I simpel run
    "metasync d32" as indicated ?

    Thanks

    Dave

    d32: Mirror
        Submirror 0: d12
          State: Needs maintenance
        Submirror 1: d22
          State: Needs maintenance
        Pass: 1
        Read option: roundrobin (default)
        Write option: parallel (default)
        Size: 4200606 blocks

    d12: Submirror of d32
        State: Needs maintenance
        Invoke: after replacing "Maintenance" components:
                    metareplace d32 c1t0d0s5 <new device>
        Size: 4200606 blocks
        Stripe 0:
            Device Start Block Dbase State Hot Spare
            c1t0d0s5 0 No Last Erred

    d22: Submirror of d32
        State: Needs maintenance
        Invoke: metasync d32
        Size: 4200606 blocks
        Stripe 0:
            Device Start Block Dbase State Hot Spare
            c1t1d0s5 0 No Okay

    d33: Mirror
        Submirror 0: d13
          State: Needs maintenance
        Submirror 1: d23
          State: Needs maintenance
        Pass: 1
        Read option: roundrobin (default)
        Write option: parallel (default)
        Size: 6298020 blocks

    d13: Submirror of d33
        State: Needs maintenance
        Invoke: after replacing "Maintenance" components:
                    metareplace d33 c1t0d0s6 <new device>
        Size: 6298020 blocks
        Stripe 0:
            Device Start Block Dbase State Hot Spare
            c1t0d0s6 0 No Last Erred

    d23: Submirror of d33
        State: Needs maintenance
        Invoke: metasync d33
        Size: 6298020 blocks
        Stripe 0:
            Device Start Block Dbase State Hot Spare
            c1t1d0s6 0 No Okay
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Alan Bird: "Netra T1 100 & 105"

    Relevant Pages