FOLLOW UP: onboard external SCSI port in V440 & SunStorage 3310

From: Grzegorz Bakalarski (G.Bakalarski_at_icm.edu.pl)
Date: 02/08/04

  • Next message: Bradley Alan: "Metainit problem - raw device for one disk is missing"
    Date: Sun, 8 Feb 2004 17:23:46 +0100
    To: sunmanagers@sunmanagers.org
    
    

    Hello All,

    Recently I've asked about SunStorage array 3310 and onboad SCSI
    controller (LSI 1030). Sad to say but I received no answers.
    Even no "Out of office" replays .... ;-)
    Maybe this happend due to MyDoom flood or maybe due to problems
    with group mail server ...?
    Anyway I'm posting the query again with additional knowledge and
    issues.
    First some answers to the original query. On board SCSI port
    (LSI 1030) works with SS 3310. And seems quite fine. Using
    RAID0 and 12 SCSI disks (72GB, 10000rmp), i got burst transfer
    rates (copying big file) arount 77MB/s. Using RAID5 and 6 disks
    I got burst transfer rates about 50MB/s ... So not too bad.

    Now the question is: if I use additional, recommended SCSI host
    controler, will I get better results ?

    Other query regards using and configuration of the array itself. I hope
    somebody is more familiar with this new stuff ....
    I'd like to use this array attached to 2 hosts (not clustered, just
    one server doing one thing, and other server doing another thing).
    I'd like first server to use half of an array and second server to use
    second half of an array. Moreover, I'd like to create one big logical
    drive on the array (e.g. RAID5 using 12 disks) and then logicaly divide
    this big drive into 2 parts (aka LUNs) and then present (map) one
    part to first SCSI port and another part to second SCSI port.
    But this seems imposible ... Isn't it ??? Looks like any logical drive
    has to be fixated to one and only one SCSI port ... I can do two
    logical drives (2x RAID5 with 6 disk each), and then map one logical
    drive to first SCSI port nad another one logical drive to second
    SCSI port but this is not the same (one server needs only space for
    keeping rarely read only data, second server needs as much speed as
    possible)
    To be honest I can say I've read all docs (about 6 PDFs) on sunsolve
    and I can't figure out ... It seems that meaning of "SCSI controller" and
    "RAID controller" are mismatched ...
    Other query: the array can be user with "single SCSI bus" or "dual SCSI bus".
    What does it realy mean, and why this makes change ? I do not plan to use
    any additional JBOD box ... The array has one RAID controller ...
    NB: just note: the interface of SS 3310 is very similar to that on Infortrend's
    EonStor arrays ...

    Kind regards,

    GB

    PS. Again: is there any summary for a query on SS3310 in dual host and/or
      clustered environment?

    ------------------------- Original Query ----------------------------
    Dear All

    Sorry for next maybe naive question:

    I've just got V440 & 3310 SCSI RAID array. I plan to connect them.
    V440 has external SCSI port (probably U320 LVD LSI,1030).
    S3310 has U160 LVD interface.
    According to S3310 web specifications, V440 is not "supported" host
    for S3310. According to S3310 Release Notes
    ( http://docs-pdf.sun.com/816-7292-17/816-7292-17.pdf)
    V440 is also not supported.
    According to above Release Notes, supported host adapters are:
    SUN PCI Dual Ultra3 X6758A (for Solaris) or Adaptec 39160 (for Windows).
    Nothing about LSI 1030 ...
    So the question is: will they (v440 & S3310) talk each other and
    will it be good solution. Or should I order additional PCI card (X6758A).

    Also: Recently, there was a query about S3310 "dual host" connected to
    two V440. But I've not seen a summary. Maybe I missed something because
    of MyDoom ??? So, is it possible? Which mode is preferred/better:
    single bus or dual bus? Any other trick of trade?

    Thanks for your valuable advices.

    Kind regards,

    GB
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers

    ----- End forwarded message -----
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Bradley Alan: "Metainit problem - raw device for one disk is missing"

    Relevant Pages

    • Summary : SCSI Bus Transition
      ... Basically, cables were ok, and it was a combination of two ... As Brad said, the controller... ... condensation on the back of the server... ... Subject: *SCSI Bus Transition* ...
      (SunManagers)
    • Re: New to array setup Win2003 Server / AHA-2940UW / SPARCstorage 214
      ... "> I have a server built with Windows 2003 Server and I have an Adaptec ... If you are just connecting the Sun Array SPARCstorage Array to the ... SCSI connector on the 2940UW, ... The 2940UW should figure out its termination automatically, ...
      (comp.periphs.scsi)
    • Re: RAID configuration with out RAID controller
      ... disks with out scsi controller, ... That's a pretty good trick to use hard drives without a controller. ... you are saying you do not have a SCSI Array Controller so you cannot create ...
      (microsoft.public.windows.server.general)
    • Re: Computer Pops???
      ... is it a raid controller? ... the scsi controller polling the scsi bus perhaps ... file server with redundant storage. ... > Larry Bellinger ...
      (rec.audio.pro)
    • Re: Exchange Server Hangs OR REBOOTS
      ... The lights on the HDD array are green in OK status. ... Storage Manager will not work with Windows 2003 Server and that this was not ... a problem with their SCSI card. ...
      (microsoft.public.exchange.admin)

  • Quantcast