spare disks on solstice disk suite

From: Chuck (steeler_dude99_at_yahoo.com)
Date: 07/30/04

  • Next message: Adams, Jonathan K. [C]: "my dumb question for today is about iPlanet LDAP and Sol8"
    Date: Fri, 30 Jul 2004 04:52:22 -0700 (PDT)
    To: sunmanagers@sunmanagers.org
    
    

    Hi sun gurus,
    I have a question about spare disks on solstice
    disk suite. Below I have a metastat listing which
    describes my setup. I have a system with a mir-
    rored and striped metadevice named d30. It
    had the 2nd disk of d32 fail, which was named
    c1t9d0s6, and solstice disk suite replaced it with
    disk c1t12d0s6. I have since replaced the def-
    ective c1t9d0s6. I was wondering if it is possible
    to just make c1t12d0s6 the 2nd disk of d32 per-
    mantly and put the new disk, c1t9d0s6, in the
    hot spare pool, hsp001.
     
    chuck
     
    ps: Of course I will need to partition the actual disk
    c1t9d0 so that all of its space sits in s6 like the
    others.
     
    hrmsold% metastat d30 hsp001
    d30: Mirror
        Submirror 0: d31
          State: Okay
        Submirror 1: d32
          State: Okay
        Pass: 1
        Read option: roundrobin (default)
        Write option: parallel (default)
        Size: 573356544 blocks
    d31: Submirror of d30
        State: Okay
        Hot spare pool: hsp001
        Size: 573356544 blocks
        Stripe 0: (interlace: 64 blocks)
            Device Start Block Dbase State Hot Spare
            c1t2d0s6 0 No Okay
            c1t3d0s6 10176 No Okay
            c1t4d0s6 10176 No Okay
            c1t5d0s6 10176 No Okay

    d32: Submirror of d30
        State: Okay
        Hot spare pool: hsp001
        Size: 573356544 blocks
        Stripe 0: (interlace: 64 blocks)
            Device Start Block Dbase State Hot Spare
            c1t8d0s6 0 No Okay
            c1t9d0s6 10176 No Okay c1t12d0s6
            c1t10d0s6 10176 No Okay
            c1t11d0s6 10176 No Okay

    hsp001: 2 hot spares
            c1t12d0s6 In use 143349312 blocks
            c1t13d0s6 Available 143349312 blocks
    Tired of spam? Yahoo! Mail has the best spam protection around
    http://mail.yahoo.com
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Adams, Jonathan K. [C]: "my dumb question for today is about iPlanet LDAP and Sol8"

    Relevant Pages

    • Re: Replacing 7133 SSA Raid 5 disk without Hot Spare
      ... After replacing the offending drive with a spare, ... is it possible to simply add the replacement disk to the array as ... I've replaced drives in the following manner with a RAID1 configuration but ... Replacing 7133 SSA Raid 5 disk without Hot Spare ...
      (AIX-L)
    • Re: SCSI Question
      ... You should be able to add a hot spare at any time. ... take a 5 disk array and convert it to a 4 disk with hot spare, ... drives in an array to be the same size. ...
      (microsoft.public.windows.server.sbs)
    • Re: Replacing 7133 SSA Raid 5 disk without Hot Spare
      ... Replacing 7133 SSA Raid 5 disk without Hot Spare ... Legg Mason therefore recommends that you do not ...
      (AIX-L)
    • Re: Resizing NTFS partition to make room for FC10
      ... I use the g4u disk cloning tool for chores like this. ... spare drive. ... Boot the resized NTFS partition. ... it still, according to fdisk, thinks its 150GB. ...
      (Fedora)
    • Re: SCSI Question
      ... take a 5 disk array and convert it to a 4 disk with hot spare, ... could add a 6th disk and configure that as a hot spare. ... drives in an array to be the same size. ...
      (microsoft.public.windows.server.sbs)