SUMMARY RE: 420R with an HBA issue

Steve.Starer_at_opco.com
Date: 09/23/04

  • Next message: Steve Roberts: "Re: Sunfire v20 network card issues"
    To: <sunmanagers@sunmanagers.org>
    Date: Thu, 23 Sep 2004 11:56:38 -0400
    
    

    OK, not quite done but here's what I've got:

    Issues were finally traced to the fact that the new HBA has a new
    WWNN/WWPN.

    Solution was to rezone the HBA, then modify the LUN masking parameters
    within the Clariion.

    Thanks go to Roman Kozello, John Malick, nouce@mighty.co.za - no name
    provided, and several others, including EMC Tech support.

    I still have some grimy details to work out with Veritas, but the hard
    stuff's done.
    My original post is below.

    Regards,

    Steve

    Morning all,
    I positive I'm missing something here....

    I have a 420R that crashed recently. It is configured as follows:
    Solaris 8, 2 Emulex HBA's connected to a Clariion CX-600 via a pair of
    Brocades. I'm running Veritas Volume Manager and File System, with DMP.
    Version is 3.5, and I think I put MP2 on it. It was running fine before
    the H/W issue, so I don't think Veritas or Solaris is a contributing
    factor.

    We traced the crash to a bad Emulex HBA and/or cable. The box wouldn't
    boot. Pull the cable to one HBA and we're good, put it back and we're
    bad. Sounds simple.

    I replaced the HBA and the cable. Now the box is up. If I run some
    simple Veritas volume manager commands like vxdisk list <diskname> I
    should see four paths to specified disk, two through each controller.
    I only see two paths , both through the one controller that wasn't
    replaced (c3).

    I see both cards generate link up events on the SAN, I can see both
    cards using the utility provided by Emulex - lputil. I have a link light
    on the Brocade connected to the replacement card. I don't see the cards
    when I try to run vxdmpadm - the Veritas utility to manage their dynamic
    multi-pathing. So I checked the disks using Solaris format. I don't see
    any disks through the replacement controller which is supposed to come
    up as c4.

    What am I missing? Should I have run a reconfiguration reboot? I did
    not. Is there something more subtle going on?

    Any ideas will be greatly appreciated!
    Thanks.

    Regards,
    Steve Starer

    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers

    This communication is for informational purposes only and nothing
    herein should be construed as a solicitation, recommendation or
    an offer to buy or sell any securities or product. The information
    contained herein has been obtained from sources believed to be
    reliable but we do not guarantee accuracy or completeness.
    Oppenheimer & Co. Inc and its affiliated companies, their officers,
    directors and employees may have a position in or, make a market
    in any securities mentioned above and, may act as an investment
    banker or advisor to such companies. Client account information
    or transaction details do not supersede mailed confirmations or
    account statements which are the only official records containing
    this information. As a matter of policy, orders are not accepted
    via e-mail or voice mail and no responsibility shall accrue
    relating to any orders placed in this manner. If this communication
    has been received in error, please delete or destroy immediately.
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Steve Roberts: "Re: Sunfire v20 network card issues"

    Relevant Pages

    • Re: Benefit of Multiple Disks in SAN Environment
      ... configure the disks in a manner that they aren't keeping up with SQL's i/o ... > We are on a Hitachi system as well for our high performance disks. ... > ATA system keeps up with the 1Gb HBA that accesses it with no problem. ... > on Win2K3 they say I need Veritas Volume Manager. ...
      (microsoft.public.sqlserver.server)
    • Re: DS10L wont boot
      ... HSG80 throught HBA. ... the PCI bus and see what happens. ... cards back in one at a time to see what hangs it. ... But when booting ...
      (comp.os.vms)