Failed memory modules

From: HRISHIKESH KULKARNI (hrk007_at_yahoo.com)
Date: 09/30/04

  • Next message: Eric Seale: "Iplanet Bounces Messages"
    Date: Thu, 30 Sep 2004 05:06:10 -0700 (PDT)
    To: sunmanagers@sunmanagers.org
    
    

    Hi all,
     From the following output for prtdiag can we assume
    that failed memory bank is still in the system or has
    been removed. We have removed one and want to confirm
    that there is none other that is also faulty and that
    the error message just indicates that removed memory
    bank is not in system.
     Is the error message same if a bad memory bank is not
    in system and also if the bad memory bank is still
    within the system which might be causing the
    confusion.
    Thanks in advance,
    Regards,
    Hrishi.

    # /usr/platform/sun4u/sbin/prtdiag -v
    System Configuration: Sun Microsystems sun4u 8-slot
    Sun Enterprise E4500/E5500
    System clock frequency: 100 MHz
    Memory size: 10240Mb

    ========================= CPUs
    =========================

                        Run Ecache CPU CPU
    Brd CPU Module MHz MB Impl. Mask
    --- --- ------- ----- ------ ------ ----
     0 0 0 400 8.0 US-II 10.0
     0 1 1 400 8.0 US-II 10.0
     2 4 0 400 8.0 US-II 10.0
     2 5 1 400 8.0 US-II 10.0
     4 8 0 400 8.0 US-II 10.0
     4 9 1 400 8.0 US-II 10.0
     5 10 0 400 8.0 US-II 10.0
     5 11 1 400 8.0 US-II 10.0
     6 12 0 400 8.0 US-II 10.0
     6 13 1 400 8.0 US-II 10.0
     7 14 0 400 8.0 US-II 10.0
     7 15 1 400 8.0 US-II 10.0

    ========================= Memory
    =========================

                                                  Intrlv.
    Intrlv.
    Brd Bank MB Status Condition Speed Factor
     With
    --- ----- ---- ------- ---------- ----- -------
    -------
     0 0 1024 Active OK 60ns 8-way
       A
     0 1 1024 Active OK 60ns 8-way
       A
     2 0 1024 Active OK 60ns 8-way
       A
     2 1 1024 Active OK 60ns 8-way
       A
     4 0 1024 Active OK 60ns 8-way
       A
     4 1 1024 Active OK 60ns 2-way
       B
     5 0 1024 Active OK 60ns 8-way
       A
     5 1 1024 Failed Unknown 60ns 1-way
     6 0 1024 Active OK 60ns 8-way
       A
     6 1 1024 Active OK 60ns 2-way
       B
     7 0 1024 Active OK 60ns 8-way
       A
     7 1 1024 Failed Unknown 60ns 1-way

    ========================= IO Cards
    =========================

         Bus Freq
    Brd Type MHz Slot Name
      Model
    --- ---- ---- ----
    --------------------------------
    ----------------------
     1 SBus 25 0 QLGC,isp/sd (block)
      QLGC,ISP1000U
     1 SBus 25 1 QLGC,isp/sd (block)
      QLGC,ISP1000U
     1 SBus 25 2 cgsix
      SUNW,501-1672
     1 SBus 25 3 SUNW,hme
     1 SBus 25 3 SUNW,fas/sd (block)
     1 SBus 25 13 SUNW,socal/sf (scsi-3)
      501-3060

    Detached Boards
    ===============
      Slot State Type Info
      ---- --------- ------
    -----------------------------------------
        3 disabled disk Disk 0: Target: 10
     Disk 1: Target: 11

    Failed Field Replaceable Units (FRU) in System:
    ==============================================
    ac unavailable on CPU Board #5
            PROM fault string: fail- mem-bank1: J3601
            Failed Field Replaceable Unit is CPU board 5
    ac unavailable on CPU Board #7
            PROM fault string: fail- mem-bank1: J3401
            Failed Field Replaceable Unit is CPU board 7

    Detected System Faults
    ======================
    PROM detected failure
            Detected Thu Sep 30 05:59:36 2004
    Board 7 fault: PROM detected
    Fault: fail- mem-bank1: J3401
            Detected Thu Sep 30 05:59:36 2004
    Board 5 fault: PROM detected
    Fault: fail- mem-bank1: J3601
            Detected Thu Sep 30 05:59:36 2004

    ========================= Environmental Status
    =========================
    Keyswitch position is in Normal Mode
    System Power Status: Redundant
    System LED Status: GREEN YELLOW GREEN
    WARNING ON ON BLINKING

    Fans:
    -----
    Unit Status
    ---- ------
    Rack OK
    Key OK
    AC OK

    System Temperatures (Celsius):
    ------------------------------
    Brd State Current Min Max Trend
    --- ------- ------- --- --- -----
     0 OK 45 44 45 stable
     1 OK 53 52 53 stable
     2 OK 47 46 47 stable
     4 OK 45 44 46 stable
     5 OK 46 46 47 stable
     6 OK 46 46 48 stable
     7 OK 48 47 49 stable
    CLK OK 40 40 40 stable

    Power Supplies:
    ---------------
    Supply Status
    --------- ------
    0 OK
    1 OK
    2 OK
    3 OK
    PPS OK
        System 3.3v OK
        System 5.0v OK
        Peripheral 5.0v OK
        Peripheral 12v OK
        Auxilary 5.0v OK
        Peripheral 5.0v precharge OK
        Peripheral 12v precharge OK
        System 3.3v precharge OK
        System 5.0v precharge OK
    AC Power OK

    ========================= HW Revisions
    =========================

    ASIC Revisions:
    ---------------
    Brd FHC AC SBus0 SBus1 PCI0 PCI1 FEPS Board
    Type Attributes
    --- --- -- ----- ----- ---- ---- ----
    ---------- ----------
     0 1 5 CPU
           100MHz Capable
     1 1 5 1 1 22
    Dual-SBus-SOC+ 100MHz Capable
     2 1 5 CPU
           100MHz Capable
     3 Unknown
           100MHz Capable
     4 1 5 CPU
           100MHz Capable
     5 1 5 CPU
           100MHz Capable
     6 1 5 CPU
           100MHz Capable
     7 1 5 CPU
           100MHz Capable

    System Board PROM revisions:
    ----------------------------
    Board 0: OBP 3.2.30 2002/10/25 14:03 POST
    3.9.30 2002/10/25 14:04
    Board 1: FCODE 1.8.28 2000/12/20 12:22 iPOST
    3.4.28 2000/12/20 12:28
    Board 2: OBP 3.2.30 2002/10/25 14:03 POST
    3.9.30 2002/10/25 14:04
    Board 4: OBP 3.2.30 2002/10/25 14:03 POST
    3.9.30 2002/10/25 14:04
    Board 5: OBP 3.2.30 2002/10/25 14:03 POST
    3.9.30 2002/10/25 14:04
    Board 6: OBP 3.2.30 2002/10/25 14:03 POST
    3.9.30 2002/10/25 14:04
    Board 7: OBP 3.2.30 2002/10/25 14:03 POST
    3.9.30 2002/10/25 14:04
    #

                    
    __________________________________
    Do you Yahoo!?
    New and Improved Yahoo! Mail - Send 10MB messages!
    http://promotions.yahoo.com/new_mail
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Eric Seale: "Iplanet Bounces Messages"