disksuite problem.

From: Langdon, Nick (nick_langdon_at_csgsystems.com)
Date: 11/29/04

  • Next message: Webmaster - ITServ GmbH: "SUMMARY: Flashing FCode to QLogic 2100 PCI"
    Date: Mon, 29 Nov 2004 11:22:44 -0000
    To: <sunmanagers@sunmanagers.org>
    
    

    Hello all,

    I'm getting the following output from metastat d21

    d21: Mirror

        Submirror 0: d22

          State: Needs maintenance

        Submirror 1: d23

          State: Needs maintenance

        Pass: 1

        Read option: roundrobin (default)

        Write option: parallel (default)

        Size: 25168392 blocks (12 GB)

    d22: Submirror of d21

        State: Unavailable

        Size: 25168392 blocks (12 GB)

        Stripe 0:

            Device Start Block Dbase State Reloc Hot Spare

            c1t8d0s0 0 No - Yes

    d23: Submirror of d21

        State: Needs maintenance

        Invoke: after replacing "Maintenance" components:

                    metareplace d21 c1t9d0s0 <new device>

        Size: 25168392 blocks (12 GB)

        Stripe 0:

            Device Start Block Dbase State Reloc Hot Spare

            c1t9d0s0 0 No Last Erred Yes

    Device Relocation Information:

    Device Reloc Device ID

    c1t9d0 Yes id1,sd@SSEAGATE_ST136403LC______LT25999700007036MDQD

    I know that one of my disks has died but from this output it looks like
    both disks have died, is this correct?

    If its just one disk that has died what is the best way to remedy this?

    Cheers

    Nick
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Webmaster - ITServ GmbH: "SUMMARY: Flashing FCode to QLogic 2100 PCI"