SUMMARY: adding EMC-CX600 LUN: format gives "drive type unknown"

rob.de.langhe_at_belgacom.be
Date: 01/25/05

  • Next message: Langdon, Nick: "Veritas Volume Manager 4.0 problems"
    Date: Tue, 25 Jan 2005 09:29:10 +0100
    To: <sunmanagers@sunmanagers.org>
    
    

    Thanks all for the answers and suggestions, some of which confirmed what
    I found out myself in the mean time: the array-support for Clariion was
    not included by default in the VxVM installation ("vxddladm listsupport
    |grep DGC")

    So I downloaded from the Veritas web site the package "CLR-ASL", which
    arranged that the disk seen through 2 HBAs, was properly identified by
    VxVM as the single and same disk.

    Some people remarked that we use Qlogic-2300 cards and suggested that
    could have been the cause of the 'problem': let me confirm that I have
    connected a large combination of SUN servers with different HBA types,
    using different drivers, to EMC disk arrays, directly attached or via
    SAN switches. It is only a matter of -indeed- properly veryfing if a
    certain combination server/HBA/driver (with or without VxVM and/or EMC's
    PowerPath) has been validated by EMC, and testing out the exact
    installation order of packages, configuration files etc to get the thing
    work. Often EMC could not indicate the precise order of installations or
    configuration details themselves. It's just a bit of initial work to
    find the right combinations, but then you're done for any further
    machine that you install with the exact same combination.
    Do never forget to do the ultimate test : force I/O to the LUNs (like a
    "verify" in "format"), verify via which HBA the traffic is going, and
    pull the plug from that HBA : the I/O should just block for a few
    seconds, then continue over the other HBA. Powerpath is handy to know
    what HBA-path is being used, but only the full-featured $$-version
    provides dual-HBA load balancing of the I/O traffic, the normal
    $-version gives just path-failover, which can only be done using
    VxVM-DMP. Or the Solaris-bundled "mpxio", for that matter.

    Cheers

    Rob

    -----Original Message-----
    From: sunmanagers-bounces@sunmanagers.org
    [mailto:sunmanagers-bounces@sunmanagers.org] On Behalf Of
    rob.de.langhe@belgacom.be
    Sent: 24 January 2005 13:57
    To: sunmanagers@sunmanagers.org
    Subject: adding EMC-CX600 LUN: format gives "drive type unknown"

    Hi,

    we have a E15K domain running Solaris-8, and connected to a SAN via
    QLogic-2300 Host Bus Adapters.

    A bunch of EMC-Symmetrix disks are already made available to the server
    and being used for filesystems through VxVM.

    Now we need to add an extra LUN coming from an EMC-Clariion CX600 array.
    The new LUN is discovered with SCSI-probing, but showing up in "format"
    as a "drive type unknown" ...

    When I try to let "format" "auto-configure" the disk type (option
    "type", then select "0. Auto-Configure") I get the message

    Auto configure failed

    Within "format", the "inquiry" option yields

    Vendor: DGC
    Product: CX700
    Revision: HP03

    In VxVM, I have added the JBOD id with

    vxddladm addjbod vid=DGC pagecode=0x83 offset=8 length=16

    The people here told me that in previous attempts to make new
    Clariion-LUNs correctly identified by Solaris on a machine that has
    already Symmetrix-LUNs, was only after a reboot ... Which is surely not
    the procedure I want to adopt (production servers, hey)

    Any suggestions what can be done about it ?

    TIA

    Rob

    **** DISCLAIMER ****
    http://www.belgacom.be/maildisclaimer
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers

    **** DISCLAIMER ****
    http://www.belgacom.be/maildisclaimer
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Langdon, Nick: "Veritas Volume Manager 4.0 problems"

    Relevant Pages

    • Re: problems with scsi_transport_fc and qla2xxx
      ... HBAs are connected to target via FC switch. ... If I have several LUNs on each HBA, ... while with Emulex a directory for every LUN is created. ... connecting between HBA and switch is pulled out/in. ...
      (Linux-Kernel)
    • Need help setting SAN boot to CLARiiON from Emulex LP9002
      ... updated to boot BIOS ... create zone so the HBA has only one logical path to the SP ... Hit ALT-E during POST to configure SAN boot. ... then prompted me to "Enter two digits of the starting LUN". ...
      (comp.arch.storage)
    • Re: Need help setting SAN boot to CLARiiON from Emulex LP9002
      ... updated to boot BIOS ... create zone so the HBA has only one logical path to the SP ... Hit ALT-E during POST to configure SAN boot. ... then prompted me to "Enter two digits of the starting LUN". ...
      (comp.arch.storage)
    • Re: Not wasting space on a RAID array?
      ... >> single external bus, I'm assuming that you're only attached to one ... >> channel of the HBA. ... Yes, but I was talking about the HBA, not the module. ... You've got a single LUN on both internal busses. ...
      (comp.unix.solaris)
    • EMC SAN storage
      ... A Raid Group with LUN is configured by engineer before. ... free SAN disks in EMC, ... how to add to cluster with VxVM and VCS? ...
      (comp.sys.ibm.pc.hardware.storage)