SUMMARY: Storedge 3511 / sccli

From: Geoff Lane (zzassgl_at_buffy.sighup.org.uk)
Date: 08/28/05

  • Next message: Harald Husemann: "Problem with Linux-based jumpstart server"
    Date: Sun, 28 Aug 2005 16:29:44 +0100
    To: sunmanagers@sunmanagers.org
    
    

    Pascal got it right straight away - memo to self... Even if Sun supply
    drivers on CD with new hardware, check the Sun web site for updates BEFORE
    installation :-)

    -----------------------------------------------------------------------------

    I can't help much on that issue since I have mainly been working with 3510FC
    so far. But I could read that you installed sccli 1.2.6. This is an old
    version and it is highly recommended to install the latest which is 2.0. You
    can find it on Sun's website following download, then storage management and
    finally "3000 product family". You may need to update the firmware on the
    disk-arrays to have all functions be supported !? Hope others will provide
    you with more information relative to your problem.

    Regards,
    /Pascal

    -----------------------------------------------------------------------------

    Geoff Lane wrote:

    >I have two Storedge 3511s and a 3510 connected via fibre and a McData fibre
    >switch to a Sun V440 running Solaris 5.9 (Generic_118558-09). The setup
    >works and I have a number of LUNs configured on the 3511s/3510 and available
    >to the V440.
    >
    >I've just installed SUNWsccli (version 1.2.6) on the server and am having
    >some problems. When I select the 3510 and use the "show disks" I can see the
    >disks on the 3510...
    >
    ># sccli
    >Available devices:
    >
    > 1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
    > 2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
    > 3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
    >
    >Please enter selection: 2
    >sccli> show disks
    >Ch Id Size Speed LD Status IDs
    >----------------------------------------------------------------------
    > 2 0 136.73GB 200MB ld0 ONLINE SEAGATE ST314680FSUN146G0307
    > 2 1 136.73GB 200MB ld0 ONLINE SEAGATE ST314680FSUN146G0307
    > [ and so on ]
    > 2 42 136.73GB 200MB ld2 ONLINE SEAGATE ST314680FSUN146G0307
    > 2 43 136.73GB 200MB ld2 ONLINE SEAGATE ST314680FSUN146G0307
    >sccli> q
    >
    >When I select a 3511, and run the "show disks" command I can't see any
    >disks...
    >
    ># sccli
    >Available devices:
    >
    > 1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
    > 2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
    > 3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
    >
    >Please enter selection: 1
    >sccli> show disks
    >sccli: retrieving disk information: error: sm_err_database_update
    >sccli>
    >
    >I get similar errors for a number of other sccli commands directed to
    >either of the 3511s.
    >
    >I can't find anything about this in SunSolve or Google. Does anybody have
    >any idea what is causing the errors?
    >
    >Thanks,
    >
    >
    >

    On Sun, Aug 28, 2005 at 03:54:18PM +0100, Geoff Lane wrote:
    > I have two Storedge 3511s and a 3510 connected via fibre and a McData fibre
    > switch to a Sun V440 running Solaris 5.9 (Generic_118558-09). The setup
    > works and I have a number of LUNs configured on the 3511s/3510 and available
    > to the V440.
    >
    > I've just installed SUNWsccli (version 1.2.6) on the server and am having
    > some problems. When I select the 3510 and use the "show disks" I can see the
    > disks on the 3510...
    >
    > # sccli
    > Available devices:
    >
    > 1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
    > 2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
    > 3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
    >
    > Please enter selection: 2
    > sccli> show disks
    > Ch Id Size Speed LD Status IDs
    > ----------------------------------------------------------------------
    > 2 0 136.73GB 200MB ld0 ONLINE SEAGATE ST314680FSUN146G0307
    > 2 1 136.73GB 200MB ld0 ONLINE SEAGATE ST314680FSUN146G0307
    > [ and so on ]
    > 2 42 136.73GB 200MB ld2 ONLINE SEAGATE ST314680FSUN146G0307
    > 2 43 136.73GB 200MB ld2 ONLINE SEAGATE ST314680FSUN146G0307
    > sccli> q
    >
    > When I select a 3511, and run the "show disks" command I can't see any
    > disks...
    >
    > # sccli
    > Available devices:
    >
    > 1. /dev/rdsk/c3t216000C0FF8090FCd0s2 [SUN StorEdge 3511 SN#0090FC](Primary)
    > 2. /dev/rdsk/c3t216000C0FF8817F6d0s2 [SUN StorEdge 3510 SN#0817F6](Primary)
    > 3. /dev/rdsk/c3t216000C0FF8920C3d0s2 [SUN StorEdge 3511 SN#0920C3](Primary)
    >
    > Please enter selection: 1
    > sccli> show disks
    > sccli: retrieving disk information: error: sm_err_database_update
    > sccli>
    >
    > I get similar errors for a number of other sccli commands directed to
    > either of the 3511s.
    >
    > I can't find anything about this in SunSolve or Google. Does anybody have
    > any idea what is causing the errors?
    >
    > Thanks,
    >
    > --
    > Geoff Lane
    > God invented SCO to give people a company to hate more than Microsoft.
    > _______________________________________________
    > sunmanagers mailing list
    > sunmanagers@sunmanagers.org
    > http://www.sunmanagers.org/mailman/listinfo/sunmanagers

    -- 
    Geoff Lane, 12 Moorside Rd, Tottington, BURY, BL8 3HW, 01204-88-3193
    Elwood: It's a 106 miles to Chicago. We've got a full tank of gas, and a
            half a pack of cigarettes. It's dark, and we're wearing sunglasses.
    Jake:   Hit it!
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers
    

  • Next message: Harald Husemann: "Problem with Linux-based jumpstart server"

    Relevant Pages

    • Storedge 3511 / sccli
      ... I have two Storedge 3511s and a 3510 connected via fibre and a McData fibre ... When I select the 3510 and use the "show disks" I can see the ... Please enter selection: 2 ... sccli> show disks ...
      (SunManagers)
    • RAID disks have same serial numbers
      ... configuration on my Sun Storedge: ... As noticeable, two disks 0.10 and 0.13 have the same serial number, ... resolve this issue and configure the disk as global-spare. ... sccli> configure global-spare 0.10 ...
      (SunManagers)
    • time to restripe a RAID0 array in StorEdge 3310
      ... I have a logical drive consisting of 2 physical disks configured as RAID 0 ... in a StorEdge 3310 SCSI array. ... sccli> add disk ld1 0.2 ... sccli: start adding disks: ld1 ...
      (comp.unix.solaris)