Activating HotSpare in A1000 with RaidManager

From: Tim Evans (tkevans_at_tkevans.com)
Date: 09/27/05

  • Next message: Stephen Smith: "Sun has a laptop (again)!"
    Date: Tue, 27 Sep 2005 17:38:33 -0400 (EDT)
    To: sunmanagers@sunmanagers.org
    
    

    I have an A1000 under control of RaidManager 6, set up for RAID 5, with 12 disks
    on one LUN. Both one of the 11 data disks *and* the hotspare have failed.

    I replaced the hotspare with a new disk, thinking it would automagically become
    active and take over for the other failed disk. RaidManager showed the LUN
    being reconstructed after installing the new disk, but now shows the hotspare in
    "standby" status.

    LUN is still showing its status as "degraded," with 10 good disks and one failed
    one.

    How do I make the current hotspare take over? Just pull the bad one?

    --
    Tim Evans, TKEvans.com, Inc.	|    5 Chestnut Court
    tkevans@tkevans.com		|    Owings Mills, MD 21117
    http://www.tkevans.com/		|    443-394-3864
    http://www.come-here.com/News/	|    
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers
    

  • Next message: Stephen Smith: "Sun has a laptop (again)!"

    Relevant Pages

    • SUMMARY: Activating HotSpare in A1000 with RaidManager
      ... > active and take over for the other failed disk. ... RaidManager showed the LUN ... >How do I make the current hotspare take over? ... I used RaidManager to delete the new hotspare, then moved the new disk into the ...
      (SunManagers)
    • SDS hotspare recommendations
      ... disk3 hotspare ... so that if either disk fails, I'll have hotspare slices for each failed ... assign each slice to a separate hotspare pool, ...
      (comp.unix.solaris)
    • SUMMARY : Raid5 under Veritas Volume Manager
      ... more than one disk without hotspare, ... So i'll know that for the next time, we should always sacrifice one disk ... Raid5 under Veritas Volume Manager ...
      (SunManagers)
    • Activating HotSpare in A1000 with RaidManager (Re-Post)
      ... Activating HotSpare in A1000 with RaidManager ... Both one of the 11 data disks *and* the hotspare have failed. ... I replaced the hotspare with a new disk, ... RaidManager showed the LUN ...
      (SunManagers)
    • Re: Smartarray 5300 & hot spare
      ... is assigned as a hot spare to all three arrays. ... Unit 0 is Lun 0. ... Spare physical drives: ... It's one spare disk per LUN and one LUN ...
      (comp.os.vms)