How to rebuild data from defective hard disk from 3510FC

From: Baby David (baby.david_at_celstream.com)
Date: 11/23/05

  • Next message: Karl.Rossing_at_Federated.CA: "6130 Admin Console Error"
    Date: Wed, 23 Nov 2005 10:01:56 +0530
    To: <sunmanagers@sunmanagers.org>
    
    

    Hi Gurus,

                    I have a Sun V440 Server connected with Sun 3510FC. Now
    a disk(146GB) got failed in a logical drive (Raid 5). It also has a
    local spare disk, when the system tried to rebuild the data in to spare
    disk it gave a error "Warning Bad block encountered 136983314(311). I
    replaced the failed one with new one and did the manual rebuild after
    47% of data transfer it is giving the same error.

    Pls. help me to solve this issue,

    David

    This message is free from Virus - IMSS
    _______________________________________________
    sunmanagers mailing list
    sunmanagers@sunmanagers.org
    http://www.sunmanagers.org/mailman/listinfo/sunmanagers


  • Next message: Karl.Rossing_at_Federated.CA: "6130 Admin Console Error"

    Relevant Pages

    • rebuild problems with ata-raid on array with freebsd native meta
      ... First of all i have a intel se7520jr2 motherboard with SATA RAID ... by creating RAID1 array in LSI Integrated RAID ... but `atacontrol rebuild ar0` always had had ENXIO ...
      (freebsd-current)
    • Re: SiI RAID 1 Problems: "You can not rebuild"
      ... Used Maxtor Power Max utility to scan for errors on my hard drives. ... Rebooted and entered the RAID utility. ... Create a new mirrored set, ... I then perform an online rebuild (which runs in the ...
      (microsoft.public.windowsxp.general)
    • Re: Bad RAID Configuration Need Rebuild 1st DC
      ... I'm told that there is a bad strip any attempts to rebuild fail even though ... So I'm looking for the best solution to backup and restore this DC! ... > I understand you one stripe is broken in the OS RAID 1 on one of your DCs. ...
      (microsoft.public.windows.server.setup)
    • Re: Asus P5Q-E
      ... When I reboot I saw the raid volume 0 being labelled in yellow as Rebuild. ... Today I found the driver associated with the volume 0 as Microsoft. ... If a shutdown is happening, there is a difference between a controlled ...
      (alt.comp.periphs.mainboard.asus)
    • Re: URGENT: Need help rebuilding iir RAID5 array with failed drive
      ... You should be able to do whatever rebuild operations ... >> you need in the BIOS I believe, but that would be an offline operation, ... > Please DONT use FreeBSD to rebuild this RAID5 unit. ... > even let you rebuild the raid. ...
      (freebsd-current)