Re: Using hot pluggable HardDrive for Data Transfer
- From: "Muhammad Salman" <salmanfaheem@xxxxxxxxx>
- Date: Fri, 10 Aug 2007 06:25:01 +0300
BismillahirRehmanirRahim
Hi All,
Just wanted to update you all about the status of this problem.
Alhumdolillaah, i able to transfer data using FC-AL Internal Disks in
Sunfire V890.
I used luxadm command for hot plugging. it went OK but it throw following
errors at Server Console on hot plugg insert and remove of FC-ACL
Hard Drives.
--------------------------------------------------------------------------------------------------------------------------------------------
prod-01 console login: Aug 6 06:23:14 prod-01 scsi: WARNING:
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e011de1e91,0 (ssd5):
Aug 6 06:23:14 prod-01 Error for Command: read(10)
Error Level: Retryable
Aug 6 06:23:14 prod-01 scsi: Requested Block: 173628912
Error Block: 173628912
Aug 6 06:23:14 prod-01 scsi: Vendor: FUJITSU
Serial Number: 0613C07T91
Aug 6 06:23:14 prod-01 scsi: Sense Key: Unit Attention
Aug 6 06:23:14 prod-01 scsi: ASC: 0x29 (<vendor unique code 0x29>), ASCQ:
0x3, FRU: 0x0
Aug 6 06:23:14 prod-01 scsi: WARNING:
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e011de1e91,0 (ssd5):
Aug 6 06:23:14 prod-01 Error for Command: read(10)
Error Level: Retryable
Aug 6 06:23:14 prod-01 scsi: Requested Block: 173628912
Error Block: 173628912
Aug 6 06:23:14 prod-01 scsi: Vendor: FUJITSU
Serial Number: 0613C07T91
Aug 6 06:23:14 prod-01 scsi: Sense Key: Unit Attention
Aug 6 06:23:14 prod-01 scsi: ASC: 0x29 (<vendor unique code 0x29>), ASCQ:
0x3, FRU: 0x0
Aug 6 06:23:14 prod-01 scsi: WARNING:
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000000878e2465,0 (ssd2):
Aug 6 06:23:14 prod-01 Error for Command: read(10)
Error Level: Retryable
Aug 6 06:23:14 prod-01 scsi: Requested Block: 194695216
Error Block: 194695216
Aug 6 06:23:14 prod-01 scsi: Vendor: HITACHI
Serial Number: 0606TWVS6M
Aug 6 06:23:14 prod-01 scsi: Sense Key: Unit Attention
Aug 6 06:23:14 prod-01 scsi: ASC: 0x29 (power on, reset, or bus reset
occurred), ASCQ: 0x0, FRU: 0x0
Aug 6 06:23:15 prod-01 scsi: WARNING:
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e011de1ec1,0 (ssd8):
Aug 6 06:23:15 prod-01 Error for Command: write(10)
Error Level: Retryable
Aug 6 06:23:15 prod-01 scsi: Requested Block: 171821184
Error Block: 171821184
Aug 6 06:23:15 prod-01 scsi: Vendor: FUJITSU
Serial Number: 0613C07T94
..
..
..
..
Aug 6 06:23:18 prod-01 scsi: WARNING:
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w21000000878e2e3f,0 (ssd0):
Aug 6 06:23:18 prod-01 Error for Command: write(10)
Error Level: Retryable
Aug 6 06:23:18 prod-01 scsi: Requested Block: 30777664
Error Block: 30777664
Aug 6 06:23:18 prod-01 scsi: Vendor: HITACHI
Serial Number: 0606TWVULT
Aug 6 06:23:18 prod-01 scsi: Sense Key: Unit Attention
Aug 6 06:23:18 prod-01 scsi: ASC: 0x29 (power on, reset, or bus reset
occurred), ASCQ: 0x0, FRU: 0x0
Aug 6 06:23:50 prod-01 picld[61]: Device DISK10 inserted
--------------------------------------------------------------------------------------------------------------------------------------------
Any idea why its like that ?
Your Junior Admin
Salman
On 8/2/07, Musa Williams <musa.williams@xxxxxxxxx> wrote:
_______________________________________________
As salaamu 'alaykum
Yes it is possible to do this
On 8/2/07, Muhammad Salman <salmanfaheem@xxxxxxxxx > wrote:
BismillahirRehmanirRahim
Hi Admins,
May i know ? is it possible to use hot pluggable HardDrive for
transfering Data from one Server to another.
Infact our Sys Admin went to leave, so i have to do all this.
we have one SunFire V890 Server , i want to transfer around 10GB Data
from this Server to another SunFire V890 Server.
I dont want to use Network link as they are in different locations and
link is capable of that.
There is no removeable media for that.
So i wanted to know ., is it possible to insert a new standalone SCSI
Disk into the SunFire V890 Server, then mount it and copy data to it.
and then installed this Disk into the Other SunFire V890 for data
Transfer.
these are production Servers so i want your experienced advise.
hope to hear soon from you.
Your Junior Admin
Salman
_______________________________________________
sunmanagers mailing list
sunmanagers@xxxxxxxxxxxxxxx
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
--
Musa Williams
sunmanagers mailing list
sunmanagers@xxxxxxxxxxxxxxx
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
- References:
- Using hot pluggable HardDrive for Data Transfer
- From: Muhammad Salman
- Using hot pluggable HardDrive for Data Transfer
- Prev by Date: EV_AGENT message error
- Next by Date: Re: ping hostname failed while ping IP_Address working Options
- Previous by thread: Using hot pluggable HardDrive for Data Transfer
- Next by thread: ping hostname failed while ping IP_Address working Options
- Index(es):
Relevant Pages
|