import raw EMC device to zone
- From: "Ronelle van Niekerk" <Ronelle.vanNiekerk@xxxxxxxxxxxxxxxx>
- Date: Mon, 10 Mar 2008 15:26:57 +0200
Guys,
I am new to this SUN containers thing and am trying to learn without the
benefit of someone who actually knows what they're doing.
I have some EMC "disks" on the global zone and would like to import them
into the two zones on that domain, but I am struggling.
I am following an example given to me by my SUN partners as follows:
global# zonecfg -z zone1
add device
set match=/dev/rdsk/c1t0d0s6
end
add device
set match=/dev/dsk/c1t0d0s6
end
I reboot the zone and zlogin to it, but nothing.
The problem is that I don't know which devices to use.
/dev/rdsk/emcpower0 and /dev/dsk/emcpower0 don't seem to work, neither
does emcpower0a.
Which devices should I be using?
And am I doing this right?
Running Solaris 10 on all globals and zones.
A format gives me these devices:
2. c1t5006016939A03A0Bd0 <DGC-RAID5-0324 cyl 61438 alt 2 hd 256
sec 20>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016939a03a0b,0
3. c1t5006016039A03A0Bd0 <DGC-RAID5-0324 cyl 61438 alt 2 hd 256
sec 20>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016039a03a0b,0
4. c1t5006016039A03A0Bd1 <DGC-RAID5-0324 cyl 51198 alt 2 hd 256
sec 16>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016039a03a0b,1
5. c1t5006016939A03A0Bd1 <DGC-RAID5-0324 cyl 51198 alt 2 hd 256
sec 16>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016939a03a0b,1
6. c1t5006016039A03A0Bd2 <DGC-RAID5-0324 cyl 51198 alt 2 hd 256
sec 16>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016039a03a0b,2
7. c1t5006016939A03A0Bd2 <DGC-RAID5-0324 cyl 51198 alt 2 hd 256
sec 16>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016939a03a0b,2
8. c1t5006016039A03A0Bd3 <DGC-RAID5-0324 cyl 61438 alt 2 hd 256
sec 20>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016039a03a0b,3
9. c1t5006016939A03A0Bd3 <DGC-RAID5-0324 cyl 61438 alt 2 hd 256
sec 20>
/pci@3,700000/SUNW,emlxs@0/fp@0,0/ssd@w5006016939a03a0b,3
10. emcpower0a <DGC-RAID5-0324 cyl 61438 alt 2 hd 256 sec 20>
/pseudo/emcp@0
11. emcpower1a <DGC-RAID5-0324 cyl 51198 alt 2 hd 256 sec 16>
/pseudo/emcp@1
12. emcpower2a <DGC-RAID5-0324 cyl 51198 alt 2 hd 256 sec 16>
/pseudo/emcp@2
13. emcpower3a <DGC-RAID5-0324 cyl 61438 alt 2 hd 256 sec 20>
/pseudo/emcp@3
-Ronelle van Niekerk
_______________________________________________
sunmanagers mailing list
sunmanagers@xxxxxxxxxxxxxxx
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
- Follow-Ups:
- remote connection failed
- From: Koray Sonmez
- remote connection failed
- Prev by Date: Require server Sizing tool
- Next by Date: MPxIO/SSTM on Sun vs HP branded QLogic HBAs
- Previous by thread: Require server Sizing tool
- Next by thread: remote connection failed
- Index(es):
Relevant Pages
- Re: Solaris 10 networking - Global zones
... we could zlogin to the zone just fine. ... plumbs the interface
on the global. ... We think it might be NIS+ related on the globals, ... (comp.unix.solaris) - DNS Zone query
... global has a DC called fr1 ... mycompay.global has a DC called DC1 ...
dc1 has a copy of fr1's zone ... even though dc1 has a copy of globals dsn zone
the lookup fails!! ... (microsoft.public.win2000.dns)