MSL5000 not responding

From: Andrew Raine (Andrew.Raine_at_mrc-dunn.cam.ac.uk)
Date: 05/05/04

  • Next message: Iain Barker: "Changing ethernet device ennumeration order"
    Date: Wed, 05 May 2004 16:45:34 +0100
    To: tru64-unix-managers@ornl.gov
    
    

    Dear Managers,

    I have a problem with a tape robot on my system, and I'd appreciate
    some help!

    I have a Tru64 5.1 pk3 cluster (ES40 + DS20) and have recently added an
    MSL5000 tape library with twp DSLT320 drives. This attaches via FC,
    and I believe that the zoning has been set up correctly:

    The system can see all the devices:

        beta # hwmgr view d
         HWID: Device Name Mfg Model Location
         ------------------------------------------------------------------------------
        
          <stuff deleted>
        
          226: /dev/ntape/tape4 COMPAQ SDLT320 bus-1-targ-0-lun-2
          227: /dev/changer/mc2 MSL5000 Series bus-1-targ-0-lun-0
          228: /dev/ntape/tape5 COMPAQ SDLT320 bus-1-targ-0-lun-1

    and I seem to be able to talk to the tape drives OK:

        beta # mt -f /dev/tape/tape4 status
        
        DEVIOGET ELEMENT CONTENTS
        ---------------- --------
        category DEV_TAPE
        bus DEV_SCSI
        interface SCSI
        device SDLT320
        
        <etc.>

    [and I see the same for tape5]

    However, I can't get the Media Robot Utility (MRU) to talk to it:

        beta # setenv MRU_ROBOT /dev/changer/mc2
        beta # robot show robot
        ROBOT /dev/changer/mc2 is not responding: Operating system specific error.

    Until the last weekend, I had an almost identical Neo Overland 2000
    system, connected by SCSI, which the MRU could see and handle fine.
    However, the Neo's SCSI bus seems to have gone down, and I need to get
    backups working again! Can anyone suggest what to look for?

    Many thanks,

    Andrew

    --
    Dr. Andrew Raine, Head of IT, MRC Dunn Human Nutrition Unit, 
    Wellcome Trust/MRC Building, Hills Road, Cambridge, CB2 2XY, UK
    phone: +44 (0)1223 252830   fax: +44 (0)1223 252835
    web: www.mrc-dunn.cam.ac.uk email: Andrew.Raine@mrc-dunn.cam.ac.uk
    

  • Next message: Iain Barker: "Changing ethernet device ennumeration order"

    Relevant Pages

    • Re: MSL5000 Tape Library tape cleaning?
      ... tape drives and 24 tape capacity. ... a cleaning tape loaded in the last slot of the tape "stacker". ... needs to be cleaned, and furthermore, if I do a $ ROBOT SHOW SLOT, ... We've gone through many tape drives over the last few years. ...
      (comp.os.vms)
    • Re: LTO-2 Ultrium tape drive and VMS
      ... I understood that the problem with LTO drives until now is that they ... do not support small blocks and thus cannot support ANSI labels. ... > Random data compressed write to the tape drive: ... > $ robot show robot gk: ...
      (comp.os.vms)
    • SUMMARY: MSL5000 not responding
      ... Colin Bull and Karl Vogel for their rapid responses (the delay in my answering ... The answer is that, in a cluster, devices visible to more than one node need ... By the way, some respondents were puzzled by the robot command, expecting me to be using mcutil and the mcicap database, which is the up-to-date way of doing ... they came on a floppy with the first tape robot I bought 4 years ago. ...
      (Tru64-UNIX-Managers)
    • Re: Questions about changing backup devices/methods
      ... I have been asked about changing the way some VMS systems are backed up. ... each system has a directly attached SCSI tape ... Other posters have cited the ROBOT software. ... The robot is found at the same SCSI ...
      (comp.os.vms)
    • 2 LPARS Sharing 3494 ATL - Why does SY1 always update TCDB ?
      ... I have just initiated sharing of our 3494 tape robot across 2 LPARS ... They have separate range of tapes, separate TCDB, separate CA1 TMC, ... Do both LPARS have to be IPL'd for category codes to be effective? ...
      (bit.listserv.ibm-main)