New tape & changer after power cycling a SAN

From: Antonio Gonzalez (antonio.gonzalez_at_terra.es)
Date: 07/29/04

  • Next message: Monostori Krisztian: "Most editor"
    Date: Thu, 29 Jul 2004 21:53:12 +0200
    To: tru64-unix-managers@ornl.gov
    
    

    We have an issue with the SAN discovering process. The config. is as follow:
    - 2 * GS1280 + cluster
    - Tru64 v5.1B pk3
    - SAN: brocade FCSWs + EVA + NSR2404 + MSL5000 (2 drives)

    Sometimes (not always !!) when we need to switch off / on all the elements
    in the site, we suffer this problem: the Unix boxes discover the tapes and
    changer as new devices, giving them the next consecutive number. So we have
    now mc4 and tape8 & tape9.
    Of course it is a serious problem for scripts that needs to be fixed each
    time.

    Actually is safer to change the name of the devices (dfsmgr -m) than touch
    the scripts.

    It could be solved doing a Persistent Binding but don't know how to set up
    that.
    We have play with some variables in the NSR without any success so far.

    HP support don't help either.

    Any hint will be welcome
    regards
    antonio


  • Next message: Monostori Krisztian: "Most editor"