HSZ70 controllers and v5.1A

From: McCracken, Denise (Denise.McCracken_at_misyshealthcare.com)
Date: 12/01/04

  • Next message: Werner.Rost_at_zf.com: "sort-Problem"
    Date: Wed, 01 Dec 2004 13:01:49 -0700
    To: "Tru64 managers' list (E-mail)" <TRU64-UNIX-MANAGERS@ornl.gov>
    
    

            In the past, we have had an issue with HSZ40 and HSZ50 controllers
    not working with 5.1a. The OS sees the controller, but not the units. We
    now know that HSZ40 and HSZ50 do not present WWIDs for their units, and the
    OS has to construct them. One of the pieces that it uses to build the WWID
    is the "Vendor Identification" string. On some HSZ's, this string is NULL,
    which prevents the OS from creating the WWID. If the vendor ID string is
    "DEC", they work fine.

            Now my question is, can an HSZ 70 controller present a WWID for each
    unit? We have some here that have blank vendor ID strings, so if they are
    unable to do this, they are going to be useless with 5.1a.

            Also, has anyone used the "dangerous" command to set the vendor ID
    string on a 70? I haven't had the nerve to try it on someone else's
    equipment.

            If I boot a system from the 5.1a CD and I can see the LUNs on the
    controller, is it safe to assume that the upgrade is going to work?

    Thanks for your time.

    -denise

    "Customer service may be the only way that a
    company can distinguish itself from its
    competition these days." -H. Frank Gibbard

    Denise McCracken, Systems Software Specialist
    Misys Healthcare Systems, Tucson, AZ

    Certified Tru64 v5 Systems Administrator
    Comptia Network+ Certified Professional


  • Next message: Werner.Rost_at_zf.com: "sort-Problem"

    Relevant Pages

    • dri hangs the pc (radeon 7000/VE, SiS645DX AGP)
      ... Memory & AGP Controller ... 00:01.0 PCI bridge: Silicon Integrated Systems [SiS] SiS 530 Virtual ... server glx vendor string: SGI ...
      (Linux-Kernel)
    • Re: Einfachste Formularverarbeitung mit JSPs?
      ... abstract void set(String id, String value); ... abstract class Controller { ... void initialize(context, HttpRequest req, HttpResponse resp) ... ... extends Controller> clazz) { ...
      (de.comp.lang.java)
    • Re: =?ISO-8859-15?Q?Schl=FCsselwortargumente?=
      ... zurückliefern soll und zwei optionale Parameter hat: "controller" und "action". ... class RenderBuilder render{ ... private final String name; ... RenderBuilder(String name, String controller, String action) { ...
      (de.comp.lang.java)
    • Re: TI Firewire Card Driver Issue
      ... My question pertains to Windows XP Pro SP2 installation of drivers for my ... Texas Instruments OHCI Compliant IEEE 1394 Host Controller (firewire card). ... you get a text string that looks like this. ...
      (microsoft.public.windowsxp.hardware)
    • Re: =?ISO-8859-15?Q?Schl=FCsselwortargumente?=
      ... zurückliefern soll und zwei optionale Parameter hat: "controller" und "action". ... class RenderBuilder render{ ... private final String name; ... RenderBuilder(String name, String controller, String action) { ...
      (de.comp.lang.java)

  • Quantcast