Date: Mon, 28 Mar 2005 08:38:31 -0800 (PST)
To: tru64-unix-managers@ornl.gov
My alpha cluster connects to raidsets on a HSG80 controller via SAN. Last
week, first one, then another disk failed on it -- fortunately, both
failed disks were in different raidsets. I unfortunately don't have a hot
spare and so the raidsets have been running reduced until the replacement
disks -- and I'm going to get a spare disk this time -- arrive. What I'd
like to know is how can I manually replace each failed disk so that each
disk goes into the correct raidset ? Also what is the procedure (and
console comands) for replacing a disk ?
SUMMARY: HSG80 failed disk replacement ... The bus with the failed disk should be quiesced prior to physically ...Replacement 'Hot Swap') which described the procedure: ... My alpha cluster connects to raidsets on a HSG80 controller via SAN. ... (Tru64-UNIX-Managers)
Re: Older StorageWorks Parts Not Available ... > Who did the parts replacement - CS or the Customer? ... you do also not simply swap bad drives with good drives ... The parts were DOA....Disk drives are designed to survive certain ... (comp.os.vms)
Re: Code density and performance? ... > unsatisfactory experience with traditional paging....MVS had two separate issues ... more efficient to select non-changed page for replacement (before ... writing a non-changed page out to disk (since the previous copy was ... (comp.arch)
Re: The zoaran curse returns ... I never used to do it much, but since my last replacement I ... but it seems like the logic board fairy is visiting me ... a repair from someone else's logic board failure). ... >> First I have to decide whether I should take out the 80GB disk I put in ... (uk.comp.sys.mac)
RE: Older StorageWorks Parts Not Available ... By the way - most Field Service companies these value their technicians ... Who did the parts replacement - CS or the Customer? ... replacement procedures - which on some controllers do require bus ... Improper eco levels (disk or controller), ... (comp.os.vms)