Shadow set problem finally solved



Well, I have posted about a shawdow set problem that I had: Hard
errors in the error log only during a shadow set merge or ANAL/DISK/
SHAD that were apparently not in blocks allocated to files.

This is a 2 disk shadowset on a DS10 running 7.3.2.

I got 2 new disks to replace the old ones.

I swapped out one disk and merged it in. But I got the same errors on
the new disk at exactly the same LBAs!

Then I swapped the other disks and merged it in. I got the same
errors on it at the same LBAs!

To be exact, I get a few more errors on the source disk for the merge,
probably due to retries, but all at the same 4 LBAs on both disks.

Here's what I think happened: Had one bad disk that had parity errors
(or a glitch that established some parity errors). Once those errors
were established, they are just copied from disk to disk every time I
merged a shadowset.

One thing I don't know is why ANAL/DISK/SHAD/BLOCKS=FILE hits these
parity errors, since all other tests indicate that the reported LBAs
are not in a file. ANAL/DISK/READ reported no errors, and DFU
indicates that the LBAs are not in a file.

To get rid of these errors I am in the process of trying this:

1. Broke a disk out of the shadow set and did an image save and
compress on it.

2. Booted on that disk and remerged the shadow set.

That merge is in progress. I will see if I have any errors on it.
.



Relevant Pages

  • HBVS on system-disk shadow set, VAXcluster, reboot, ANA/DISK/REPAIR
    ... This is a long post involving the nitty-gritty of HBVS of a system disk. ... in a cluster, I don't mount any disks except the system disk (most ... I reboot after patch installation, it's not worth it to join the ... Physically remove one member of the system-disk shadow set, ...
    (comp.os.vms)
  • Re: Errors during shadow set merge
    ... I have been getting errors during shadow set merges since ... the warning you are going to get that the disk is failing! ... touched the media error is noted. ... the drives generally handle their own bad block replacement. ...
    (comp.os.vms)
  • Re: Errors during shadow set merge
    ... I have been getting errors during shadow set merges since I bought ... you are going to get that the disk is failing! ... different LBAs it means the situation is deteriorating and you may have ... This is indicative of the problem - a media failure - and not one of ...
    (comp.os.vms)
  • Re: Errors during shadow set merge
    ... I have been getting errors during shadow set merges since I bought ... you are going to get that the disk is failing! ... different LBAs it means the situation is deteriorating and you may have ...  I checked the error log more ...
    (comp.os.vms)
  • Re: Errors during shadow set merge
    ... you are going to get that the disk is failing! ... If you don't have a service contract, order a replacement disk and get a ... These error bursts only happen when I do a shadow set merge. ...
    (comp.os.vms)