What do do about these errors?



I am getting 3 or 4 errors like this on DKA100 on most days.

I have DKA100 is in a shadowset with one other disk. I am not
getting errors on other SCSI devices.

I guess I should replace the disk ASAP?

Thanks for any input.


**** V3.4 ********************* ENTRY 7124
********************************


Logging OS 1. OpenVMS
System Architecture 2. Alpha
OS version V7.3-2
Event sequence number 20393.
Timestamp of occurrence 05-JAN-2011 02:22:42
Time since reboot 130 Day(s) 15:14:14
Host name EESD

System Model AlphaServer DS10 617 MHz

Entry Type 1. Device Error


---- Device Profile ----
Unit $1$DKA100
Product Name ATLAS10K2-TY184L
Vendor QUANTUM

-- Driver Supplied Info -
Device Firmware Revision DA40
VMS SCSI Error Type 5. Extended Sense Data from Device
SCSI ID x01
SCSI LUN x00
SCSI SUBLUN x00
Port Status x00000001 NORMAL - normal successful
completion
SCSI Command Opcode x2A Write (10 byte command)
Command Data
x00
x00
x5C
xDB
xD6
x00
x00
x14
x00

SCSI Status x02 Check Condition
Remaining Byte Length 18.

--- Device Sense Data ---

Error Code xF0 Current Error
Information Bytes are Valid
Segment # x00
Information Byte 3 x00
Byte 2 x5C
Byte 1 xDB
Byte 0 xE0 LBA: x005CDBE0
Sense Key x01 Recovered Error
Additional Sense Length x0A
CMD Specific Info Byte 3 x01
Byte 2 xD2
Byte 1 x0B
Byte 0 x58
ASC & ASCQ x0C01 ASC = x000C
ASCQ = x0001
Write Error Recovered with Auto
Reallocation
FRU Code x00
Sense Key Specific Byte 0 x80 Valid Sense Key Data
Byte 1 x00
Byte 2 x08

----- Software Info -----
UCB$x_ERTCNT 16. Retries Remaining
UCB$x_ERTMAX 16. Retries Allowable
IRP$Q_IOSB x0000000000000000
UCB$x_STS x08020810 Online
UCB$x_STS x08020810 Online
Software Valid
Volume is Valid on the local node
Unit supports the Extended
Function bit
IRP$L_PID x82640600 Requestor "PID"
IRP$x_BOFF 6144. Byte Page Offset
IRP$x_BCNT 10240. Transfer Size In Byte(s)
UCB$x_ERRCNT 68. Errors This Unit
UCB$L_OPCNT 26314286. QIO's This Unit
ORB$L_OWNER x00010004 Owners UIC
UCB$L_DEVCHAR1 x1C4D4008 Directory Structured
File Oriented
Sharable
Available
Mounted
Error Logging
Capable of Input
Capable of Output
Random Access

.



Relevant Pages

  • hardware errors?
    ... the DS20E's internal scsi disk suffered a mount-verify-timeout. ... The following day the system disk (a mirrored set inside the raid array) errored. ... Port: x01 Target: x01 LUN: x00 ...
    (comp.os.vms)
  • Re: Errors during shadow set merge
    ... you are going to get that the disk is failing! ... If you don't have a service contract, order a replacement disk and get a ... These error bursts only happen when I do a shadow set merge. ...
    (comp.os.vms)
  • SUMMARY: Disk drive errors - is the drive dead?
    ... The most valuable hint came from Selden, who pointed out that ``errors on a ... CMD SPECIFIC 3 x00 ... and the disk drives manual, which lists ``Synchronous Data Transfer error: ...
    (Tru64-UNIX-Managers)
  • Errors during shadow set merge
    ... I have been getting errors during shadow set merges since I bought ... Sense Key Specific Byte 0 x80 Valid Sense Key Data ...
    (comp.os.vms)
  • Re: Errors during shadow set merge
    ... I have been getting errors during shadow set merges since I bought ... If you don't have a service contract, order a replacement disk and get a rush on the delivery! ...
    (comp.os.vms)