HSZ50 problem
From: Chris Scheers (chris_at_applied-synergy.com)
Date: 01/25/04
- Next message: riedo: "For Sale Alpha-server"
- Previous message: Emeric Maschino: "Switching from AlphaBIOS to SRM on AlphaPC LX164"
- Next in thread: Richard B. Gilbert: "Re: HSZ50 problem"
- Reply: Richard B. Gilbert: "Re: HSZ50 problem"
- Reply: Stuart Fuller: "Re: HSZ50 problem"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Date: Sun, 25 Jan 2004 00:23:41 -0600
I have an HSZ50 that has been off for a couple of months while things
were being moved and rewired.
Upon turning it back on, the controller now fails power up with the
first two lights lit, and displays:
Mist Diag Error 00000030
Mist Diag Param1 A3FFFFFC
Mist Diag Param2 04000000
Mist Diag Param3 BB00000D
I can't find a description of this in the service manual.
What is the meaning of this, can I fix it, etc.?
In addition to the information above, more data is dumped. If
necessary, I can get this. (The system isn't wired up to something I
can cut and past from yet.)
Thanx!
-----------------------------------------------------------------------
Chris Scheers, Applied Synergy, Inc.
Voice: 817-237-3360 Internet: chris@applied-synergy.com
Fax: 817-237-3074
- Next message: riedo: "For Sale Alpha-server"
- Previous message: Emeric Maschino: "Switching from AlphaBIOS to SRM on AlphaPC LX164"
- Next in thread: Richard B. Gilbert: "Re: HSZ50 problem"
- Reply: Richard B. Gilbert: "Re: HSZ50 problem"
- Reply: Stuart Fuller: "Re: HSZ50 problem"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]