Re: HSZ50 problem

From: Stuart Fuller (stufuller_at_usa.net)
Date: 01/25/04

  • Next message: Ben: "TK85-BX drive"
    Date: Sun, 25 Jan 2004 10:18:19 -0500
    
    

    Chris Scheers wrote:

    > I have an HSZ50 that has been off for a couple of months while things
    > were being moved and rewired.
    >
    > Upon turning it back on, the controller now fails power up with the
    > first two lights lit, and displays:
    >

    If by "first two lights", you're referring to lights 5 and 6, then this
    indicates:

            NVMEM write error : replace controller module

    Or, if you referring to lights 1 and 2 blinking, then this indicates:

            Journal SRAM is bad : replace controller module

    -- 
            Stu
    

  • Next message: Ben: "TK85-BX drive"

    Relevant Pages

    • Re: HSZ50 problem
      ... > Upon turning it back on, the controller now fails power up with the ... Or, if you referring to lights 1 and 2 blinking, then this indicates: ...
      (comp.os.vms)
    • Re: HSZ50 problem
      ... > Chris Scheers wrote: ... >> Upon turning it back on, the controller now fails power up with the ... I'm sure the standard response is "replace controller module". ...
      (comp.os.vms)
    • Re: LED Traffic light flash
      ... it is the controller which dims the intersection. ... > a method of dimming the intersection really does a number on the NEMA ... but all the lights can be seen on the intersection. ... LED signals regulate the current through the LEDs so that they can ...
      (sci.electronics.design)
    • Re: Intermittent operation of 3 appliance modules AM486
      ... Christmas lights in season and just a couple of other lights during ... Although I have read and extensively researched for trouble-shooting ... CM11 Computer interface, programmed and disconnected from my PC ... so I could test from my sundowner controller. ...
      (comp.home.automation)
    • Re: Intermittent operation of 3 appliance modules AM486
      ... Christmas lights in season and just a couple of other lights during ... CM11 Computer interface, programmed and disconnected from my PC ... having issues with three of the AM486's on one end of my house. ... so I could test from my sundowner controller. ...
      (comp.home.automation)