Re: pws 500au problems

From: Tom Linden (tom_at_kednos.com)
Date: 09/08/05

  • Next message: S: "Re: pws 500au problems"
    Date: Wed, 07 Sep 2005 16:48:31 -0700
    
    

    On Thu, 8 Sep 2005 01:25:27 +0200, Peter Huybrechts <m713007@hotmail.com>
    wrote:

    > ok guys.. everything seems to work fine now.
    > I was a little too quick with my reactions.
    > removal of the battery worked, and have put the default rom (via cmos
    > setup)
    > to SRM.
    > now it's an au system.. OpenVMS will install fiine.
    >
    > Thanks to everybody who responded so quick !
    > :-)))
    >
    >
    > "Peter Huybrechts" <m713007@hotmail.com> wrote in message
    > news:431f4782$0$6578$ba620e4c@news.skynet.be...
    >> Hi,
    >> I bought a pws 500au but this machine gives some problems.
    >> The Powerup Codes of the leds give code E4 (Memory address line error).
    >> The system boots into FreeBSD and seems to work ok. Problem is I can't
    >> get
    >> it into SRM mode.... Pressing Ctrl-C at boot time, nor disconnecting
    >> boot
    >> drive works.
    >> Somebody any Idea what's wrong ? (maybe something wrong in the flash rom
    >> ??)

    The difference between A and AU or Miata and Miata GL were two that I can
    think of,
    The GL remebers the state of the power switch after interruption and will
    power
    itself backup assuming AUTO_ACTION is set to restart and GL had onboard
    SCSI.

    BTW. I have previously posted the dip switch setting to run this at
    600MHz, which
    I have successfully done on both 500's and 433's. It will not cause any
    damage.
    >>
    >> Thanks,
    >> Peter
    >>
    >
    >


  • Next message: S: "Re: pws 500au problems"

    Relevant Pages

    • Re: pws 500au problems
      ... >> The system boots into FreeBSD and seems to work ok. ... The difference between A and AU or Miata and Miata GL were two that I can ... The GL remebers the state of the power switch after interruption and will ... I have previously posted the dip switch setting to run this at ...
      (comp.os.vms)
    • SUMMARY: PWS500 Power Switch again
      ... and the Miata GL, the latter would remember the state of the ... power switch through ... Incoming mail is certified Virus Free. ... Checked by AVG anti-virus system. ...
      (Tru64-UNIX-Managers)
    • SUMMARY: PWS500 Power Switch again
      ... Several people have indicated that there was a difference between the Miata ... Subject: Re: PWS500 Power Switch again ... Incoming mail is certified Virus Free. ... Checked by AVG anti-virus system. ...
      (comp.os.vms)