Re: ISL boot DVD

From: Ken (KenPerl_at_gmail.com)
Date: 10/27/05


Date: 26 Oct 2005 18:19:53 -0700

I can't enter the BCH prompt, when the system is warm-up it stops at a
message like this,
************* SYSTEM ALERT **************
SYSTEM NAME: gsp
DATE: 10/27/2005 TIME: 01:13:59
ALERT LEVEL: 6 = Boot possible, pending failure - action required

REASON FOR ALERT
SOURCE: 6 = platform
SOURCE DETAIL: 3 = cabinet fan SOURCE ID: 0
PROBLEM DETAIL: 4 = fan failure

LEDs: RUN ATTENTION FAULT REMOTE POWER
       FLASH FLASH OFF ON ON
LED State: Running non-OS code. Non-critical error detected.
Check Chassis and Console Logs for error messages.

0x002000646300405F 00000000 00000000 - type 0 = Data Field Unused
0x582008646300405F 00006909 1B010D3B - type 11 = Timestamp 10/27/2005
01:13:59
A: ack read of this entry - X: Disable all future alert messages
Anything else skip redisplay the log entry
->Choice:a
*****************************************
the system doesn't ask me if I want to interact with ISL too.
I searched google and docs.hp.com and don't find any userful tips.



Relevant Pages

  • [HPADM] Memory checksum Errors in rp2470
    ... - Is this a critical error because of faulty memory modules? ... REASON FOR ALERT ... Check Chassis and Console Logs for error messages. ... Anything else redisplay the log entry ...
    (HP-UX-Admin)
  • Re: Endless Intrusion Alerts
    ... Try setting the rule which blocks port 135 so it wont popup you the alert ... just make a log entry ... > service in Norton has recently got turned on. ... > a critical nature. ...
    (microsoft.public.security.virus)