> >We have a peculiar problem with one of our Octane. We recently
> >moved our 9 SGI (2 O200, 2 Octane2 and 5 Octane) from a 10 MB/sec
> >to a 100 MB/sec switch and of the 5 Octane, one does not
> >communicate at all when plugged in the 100MB/sec switch but works
> >perfectly well at 10 MB/sec (port f0).
> [ ... ]
>
> Try forcing both ends of the connection to matching duplex settings.
I've had similar problems with my Onyx1 (using an AUI-cat5 transciever) and
a 100mb switch. I couldn't get it to work at all (tried different forced
speeds and duplex settings). In the end I had use a 10mb hub between the
Onyx and the 100mb switch which fixed it!