Cannot configure A1000 Array on Sun Fire V240

From: Samurai-AL (alind_at_joho.com)
Date: 04/11/05


Date: 11 Apr 2005 02:29:00 -0700

Hi,
I picked up an A1000 second hand (it had no disks in it).
I threw a 36Gb Sun Hard disk into slot 0 and tried to set it up on a
Sun Fire V240, but no luck.
I connected to the A1000 serial port and loaded the following files via
XModem:
03010400.bwd
03010468.apd
I found these files on the V240 after I installed rm6221 and
112126-09.zip

ok reset-all

Sun Fire V240, No Keyboard
Copyright 1998-2003 Sun Microsystems, Inc. All rights reserved.
OpenBoot 4.11.4, 2048 MB memory installed, Serial #56796109.
Ethernet address 0:3:ba:62:a3:cd, Host ID: 8362a3cd.

ok probe-scsi-all
/pci@1c,600000/scsi@2,1

/pci@1c,600000/scsi@2
Target 0
  Unit 0 Disk FUJITSU MAN3367M SUN36G 1502
Target 1
  Unit 0 Disk FUJITSU MAN3367M SUN36G 1502
Target 2
  Unit 0 Disk FUJITSU MAN3367M SUN36G 1502
Target 3
  Unit 0 Disk FUJITSU MAN3367M SUN36G 1502

/pci@1e,600000/scsi@2,1

/pci@1e,600000/scsi@2
Target 1
  Unit 0 Device type 20 Symbios StorEDGE A1000 0301
  Unit 1 Device type 20 Symbios StorEDGE A1000 0301
  Unit 2 Device type 20 Symbios StorEDGE A1000 0301
  Unit 3 Device type 20 Symbios StorEDGE A1000 0301
  Unit 4 Device type 20 Symbios StorEDGE A1000 0301
  Unit 5 Device type 20 Symbios StorEDGE A1000 0301
  Unit 6 Device type 20 Symbios StorEDGE A1000 0301
  Unit 7 Device type 20 Symbios StorEDGE A1000 0301

ok boot -r
Boot device: /pci@1c,600000/scsi@2/disk@0,0 File and args: -r
SunOS Release 5.9 Version Generic_118558-04 64-bit
Copyright 1983-2003 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
WARNING: forceload of misc/md_trans failed
WARNING: forceload of misc/md_raid failed
WARNING: forceload of misc/md_hotspares failed
WARNING: forceload of misc/md_sp failed
Hardware watchdog enabled
configuring IPv4 interfaces: bge0 bge1.
Hostname: cgp
Configuring /dev and /devices
Configuring the /dev directory (compatibility devices)
Error while creating disks RDAC Symbolic Links: Unable to read
/etc/osa/mnf or create /tmp/disksmnf.87
Re-generating rdriver.conf file ...
drvconfig: driver failed to attach: rdriver
Configuring the RAID devices
Error while creating disks RDAC Symbolic Links: Unable to read
/etc/osa/mnf or create /tmp/disksmnf.343
The system is coming up. Please wait.
checking ufs filesystems
/dev/md/rdsk/d107: is logging.
/dev/md/rdsk/d104: is logging.
/dev/md/rdsk/d106: is logging.
starting rpc services: rpcbind done.
Setting netmask of bge0 to 255.255.255.0
Setting netmask of bge0:1 to 255.255.255.0
Setting netmask of bge1 to 255.255.255.0
Setting netmask of bge1:1 to 255.255.255.0
Setting default IPv4 interface for multicast: add net 224.0/4: gateway
cgp
syslog service starting.
Starting CommuniGate Pro
There are no devices (controllers) in the system; nvutil terminated.
There are no devices (controllers) in the system.

fwutil failed!
Array Monitor initiated
RDAC daemons initiated
Apr 11 18:11:26 cgp /usr/lib/osa/bin/arraymon: No RAID devices found to
check.
Apr 11 18:11:27 cgp rdriver: ID[RAIDarray.rdaemon.1001] RDAC Resolution
Daemon locked in memory
Apr 11 18:11:28 cgp htt[716]: Error : Another IIIMP Server might be
running.
Backup Exec -- Unix Agent, Version 5.01 Revision 5.046
Copyright 2001 VERITAS Software Corporation. All Rights Reserved.
Set Signal Complete
Initial Config Complete
<UPSilon>
<UPSilon> Copyright(C) 1998 Mega System Technologies, Inc.
Copyright(C) 1998 Mega System Technologies, Inc.
<UPSilon> Ver. 2.1
Ver. 2.1
<UPSilon> Start Running!
Start Running!
volume management starting.
The system is ready.

cgp console login: root
Password:
Last login: Mon Apr 11 17:56:59 on console
Apr 11 18:11:42 cgp login: ROOT LOGIN /dev/console
Sun Microsystems Inc. SunOS 5.9 Generic May 2002

bash-2.05# /usr/lib/osa/bin/hot_add
drvconfig: driver failed to attach: ssd
WARNING: set_drivers: No arrays were found that are controlled by
either the sd or the ssd driver
bash-2.05# /usr/sbin/osa/nvutil -v
There are no devices (controllers) in the system; nvutil terminated.
bash-2.05#

Running rm6 loads up the XWindows app but says it cannot find any
devices.

###################################################
### ###
### LSI Logic Series 3/4 SCSI RAID Controller ###
### Copyright 2001, LSI Logic Inc. ###
### ###
### Sun Microsystems RAID Controller ###
### Serial number: 1T91758574 ###
### ###
###################################################

Send <BREAK> for shell access or baud rate change

.WARN: Battery Age has exceeded specified limit.
NOTE: lockMgr Role is Master

BootWare Package - Version 03.01.04.00 (Built 04/05/01 08:47:01)
RAID Controller Build Package - Version 03.01.04.68 (Built 06/22/01
15:01:13)

## SNAME COMPONENT NAME VERSION DATE
TIME
== ===== ================================ =========== ========
========
 1 .BW BootWare 03.01.04.00 04/05/01
08:47:01
 2 CFG Configuration Manager 03.01.04.68 06/22/01
15:04:03
 3 CMD Command Handlers 03.01.04.68 06/22/01
15:06:57
 4 DST Destination Driver 03.01.04.68 06/22/01
15:07:36
 5 EEL Error/Event Logger 03.01.04.68 06/22/01
15:08:09
 6 IOP I/O Path 03.01.04.68 06/22/01
15:10:06
 7 PSV Platform Service 03.01.04.68 06/22/01
15:11:11
 8 RDM RDAC Manager 03.01.04.68 06/22/01
15:12:55
 9 SOD Start of Day 03.01.04.68 06/22/01
15:14:22
10 SRC Source Driver 03.01.04.68 06/22/01
15:15:16
11 SRM Serial Raid Manager 03.01.04.68 06/22/01
15:15:43
12 SSM Subsystem Monitor 03.01.04.68 06/22/01
15:16:40
13 UTM Universal Transport Mechanism 03.01.04.68 06/22/01
15:17:13
14 KWRP Kernel Wrapper 03.01.04.68 06/22/01
15:17:40
15 VUS Virtual User Services 03.01.04.68 06/22/01
15:17:55
16 NCM Network Configuration Manager 03.01.04.68 06/22/01
15:20:50
17 .AP RAID Controller Build 03.01.04.68 06/22/01
15:01:13
18 CACH I/O Caching 03.01.04.68 06/22/01
15:02:53
19 HSM Hot Swap Monitor 03.01.04.68 06/22/01
15:08:24
20 RPA Raid Parity Assist 03.01.04.68 06/22/01
15:13:24
21 RTR Router 03.01.04.68 06/22/01
15:13:43

WARN: Using default Logical Unit ownership and Active/Passive
controller mode
NOTE: CCM: Changing default demand cache flush values
.NOTE: CCM: Changing default demand cache flush values
WARN: CCM Init Complete: Cache Store Write Error.
NOTE: RDAC Mode is Active-Passive.
NOTE: Auto LUN Transfer option not set.
NOTE: Controller Mode Active. SCSI IDs (host 1, drive 7).
NOTE: No Logical Units Owned
NOTE: Alt. Ctrl. Mode Passive (Absent/Not Failed). SCSI IDs (host ff,
drive ff)
.
NOTE: No Logical Units Owned
..

Allan Lind
Joho Technology Inc.
Sakurai Building 2F
Shiba 3-25-6, Minato-ku,
Tokyo 105-0014, Japan
Tel +81 3 5730-2766 Fax +81 3 5730-2769
Direct Phone +81 3 5730-2771
http://www.joho.com/