Problem replacing disk in StorEdge T3
From: Erlend Leganger (noname_at_nodomain.no)
Date: 10/05/05
- Next message: Thomas Orgelmacher: "Re: ? Fram buffer for Ultra 5"
- Previous message: sqrfolkdnc: "Re: problems with Apex 8001/KVM-DT KVM switch"
- Next in thread: Jeroen Besse: "Re: Problem replacing disk in StorEdge T3"
- Reply: Jeroen Besse: "Re: Problem replacing disk in StorEdge T3"
- Reply: John S.: "Re: Problem replacing disk in StorEdge T3"
- Reply: Trinean: "Re: Problem replacing disk in StorEdge T3"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Date: Wed, 05 Oct 2005 23:49:22 +0200
At work we have a T3 where all disks are configured for RAID5. One of
the disks has failed, which means that accessing the data on the T3 is
really slow.
When I entered the replacement disk, it seemed to be taken in use
automatically (proc list showed some progress), but then it failed with
a 0D status (see vol stat, fru stat etc below).
I noticed that the disk is not exactly the same as the other, could this
be the reason? It is a proper replacement disk bought from Sun with the
proper bracket and everything, so it should work or what? What can I do
to fix this?
-- - Erlend Leganger T300 Release 1.17b 2001/05/31 17:47:22 Copyright (C) 1997-2001 Sun Microsystems, Inc. All Rights Reserved. bigdaddy:/:<1>vol stat v0 u1d1 u1d2 u1d3 u1d4 u1d5 u1d6 u1d7 u1d8 u1d9 mounted 0D 0 0 0 0 0 0 0 0 bigdaddy:/:<2>fru list ID TYPE VENDOR MODEL REVISION SERIAL ------ ----------------- ----------- ----------- -------- -------- u1ctr controller card SLR-MI 375-0084-02- 0210 022813 u1d1 disk drive SEAGATE ST336605FSUN A338 3FP0H63D u1d2 disk drive SEAGATE ST336704FSUN A42D 3CD0VFBL u1d3 disk drive SEAGATE ST336704FSUN A42D 3CD0T89W u1d4 disk drive SEAGATE ST336704FSUN A42D 3CD0VCZ4 u1d5 disk drive SEAGATE ST336704FSUN A42D 3CD0VF5L u1d6 disk drive SEAGATE ST336704FSUN A42D 3CD0TG33 u1d7 disk drive SEAGATE ST336704FSUN A42D 3CD0TT8G u1d8 disk drive SEAGATE ST336704FSUN A42D 3CD0VD4T u1d9 disk drive SEAGATE ST336704FSUN A42D 3CD0TXQF u1l1 loop card SLR-MI 375-0085-01- 5.02 Flash 033179 u1l2 loop card SLR-MI 375-0085-01- 5.02 Flash 030038 u1pcu1 power/cooling unit TECTROL-CAN 300-1454-01( 0000 028800 u1pcu2 power/cooling unit TECTROL-CAN 300-1454-01( 0000 028799 u1mpn mid plane SLR-MI 370-3990-01- 0000 021282 bigdaddy:/:<3>fru stat CTLR STATUS STATE ROLE PARTNER TEMP ------ ------- ---------- ---------- ------- ---- u1ctr ready enabled master - 30.5 DISK STATUS STATE ROLE PORT1 PORT2 TEMP VOLUME ------ ------- ---------- ---------- --------- --------- ---- ------ u1d1 ready disabled data disk ready ready 30 v0 u1d2 ready enabled data disk ready ready 33 v0 u1d3 ready enabled data disk ready ready 34 v0 u1d4 ready enabled data disk ready ready 32 v0 u1d5 ready enabled data disk ready ready 33 v0 u1d6 ready enabled data disk ready ready 33 v0 u1d7 ready enabled data disk ready ready 36 v0 u1d8 ready enabled data disk ready ready 32 v0 u1d9 ready enabled data disk ready ready 32 v0 LOOP STATUS STATE MODE CABLE1 CABLE2 TEMP ------ ------- ---------- ------- --------- --------- ---- u1l1 ready enabled master - - 27.0 u1l2 ready enabled slave - - 27.5 POWER STATUS STATE SOURCE OUTPUT BATTERY TEMP FAN1 FAN2 ------ ------- --------- ------ ------ ------- ------ ------ ------ u1pcu1 ready enabled line normal fault normal normal normal u1pcu2 ready enabled line normal fault normal normal normal bigdaddy:/:<4>exit Connection closed by foreign host.
- Next message: Thomas Orgelmacher: "Re: ? Fram buffer for Ultra 5"
- Previous message: sqrfolkdnc: "Re: problems with Apex 8001/KVM-DT KVM switch"
- Next in thread: Jeroen Besse: "Re: Problem replacing disk in StorEdge T3"
- Reply: Jeroen Besse: "Re: Problem replacing disk in StorEdge T3"
- Reply: John S.: "Re: Problem replacing disk in StorEdge T3"
- Reply: Trinean: "Re: Problem replacing disk in StorEdge T3"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Relevant Pages
|
Loading