Re: Merge Installation/Configuration Problem on OpenServer 5.0.7
From: Transpower (transpower_at_aol.com)
Date: 08/08/03
- Next message: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Previous message: Yves Leclerc: "Re: Using ttyvc0 device name instead of tty01"
- In reply to: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Next in thread: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Reply: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Date: 08 Aug 2003 20:35:10 GMT
Tony:
>Think you might consider a fresh install?
Nah, here's an old repost of mine from 1998, which gives the Steps to Go from
5.0.2 to 5.0.4. I don't think you understand real-world implementations very
well, but I do like your Web site.
S T E P S T O G O F R O M
S C O 5.02 T O 5.04
by
Ronald W. Satz, Ph.D., Certified Systems Engineer
May 7, 1998
1. For safekeeping and easy restoration, copy special configuration files to a
special files directory on a secondary hard drive, e.g. an Iomega Jaz drive.
These files include hwconfig -h (piped to a file and printed out; contains
interrupts and hardware addresses; annotate the printout with video driver
information), /etc/conf/cf.d/mscsi (the list of SCSI devices and ID numbers),
/etc/rc.d/2/mntfs (the list of file systems to mount after normal booting,
including the above secondary drive), /etc/hosts, /etc/ttytype, /etc/inittab,
/etc/passwd, /usr/spool/cron/crontabs/root, /.profile, /usr/lib/uucp/Devices,
/usr/spool/lp/admins/lp/printers/*, /usr/spool/lp/admins/lp/interfaces/*,
/usr/spool/lp/default, /usr/spool/fax/faxconfig (Arnet fax configuration),
/usr/vsifax3/lib/vsisrv.ini (VSI-Fax configuration),
/usr/vsifax3/lib/printers.lst, /usr/vsifax3/lib/mailers.lst,
/usr/vsifax3/lib/retrys.lst, /etc/visfax3.sh, /etc/default/merge (various
default settings for Merge), autoexec.bat and config.sys (for DOS under Merge).
To be extra safe, make hard copies of all these files and place in a labeled
folder. This folder should also have a list of all UNIX and Gateway for
Netware printers and their configurations, a list of all Equinox serial ports
and their configuration (obtained by running ssdiag), a list of all Boundless
multiconsole units and their configurations (obtained by running srstat, srstat
-c 0, srstat -c 1, etc.), a list of all data and fax modems and their
configurations, and a list of all mice and their configuration (from mkdev
mouse). (Most of these files will not copy over in a non-destructive restore
so they must be re-installed separately.) Be sure to have already downloaded
the latest drivers from Boundless (3.07, with a Merge 4 fix) and from Equinox
(3.32c) and have made the appropriate diskettes (using dd) for later use by
custom. Copy the three Boundless replacement files (serialOsa, update, and
Xsco) to the special files directory. Also include a list of all Mail aliases.
Note objects on X-Windows desktops of users. Make a second labeled folder to
contain all software licenses, certificates, and registration numbers.
2. Make a text list of all other directories and files (including all
application programs and users) to be restored to the new system. Call this
file "mustsave" and copy it to the special files directory. (These files will
copy over in a non-destructive restore.)
3. Make CTAR master backup of 5.02 system and verify that it has no errors
whatsoever.
4. Shutdown the system and reboot on the 5.04 installation diskette. Use new
license numbers if necessary. From the msci file listing, enter the correct
SCSI ID for the CDROM drive.
5. Begin fresh install, since in-place install doesn't work. Set up monitor,
video board, keyboard, and mouse as on 5.02 system (refer to data gathered in
step 1). Set up the network card using the same TCP/IP and domain information
as on 5.02 system. Choose to install Gateway for Netware. Keep existing file
layout.
6. The fresh install program should copy all operating system files and relink
the kernel without problems. When finished, shutdown and reboot.
7. Install SCO SMP software (using the Software Manager (custom)). License
each additional CPU. Install RS504C and OSS469. Relink kernel and reboot.
8. Install OSS474A (license manager for Merge 4). Install Merge 4 and license
it. Relink kernel and reboot. Add test user (because Windows 95 will not
install for root), log in as test user, and install (from Merge setup) Windows
95 from its CD. Select Merge mouse and monitor. Windows 95 should then appear
in its own X-window.
9. Install OSS449F for 5.04 to patch TCP/IP files. Relink kernel and reboot.
10. Check that Gateway for Netware is installed. If not, install it now;
relink kernel and reboot.
11. Install any other optional SCO programs (from the 5.04 CD or the Merge CD)
at this time; relink kernel and reboot.
12. Install DAT tape drive SCSI driver, using mkdev tape. Use SCSI ID from
the mscsi printout. Device is /dev/rStp0. Relink kernel and reboot.
13. Install CTAR and configure it. Test the tape drive by retensioning the
tape (use the CTAR utilities). Create emergency boot and root diskettes.
14. Do master CTAR backup of all that has been done to this step. If problems
occur after this step, we can always do a fresh restore of this tape.
15. Run mkdev hd to add the drive or drives listed in the mntfs file. Be sure
not to disturb the contents of these drives (usually accept the default
settings offered by the mkdev hd program). Relink kernel. Edit the mntfs file
manually to match the printout in the folder. Reboot. Make sure the secondary
drive is recognized by the system on startup. The special files directory on
the secondary hard drive should now be accessible.
16. Before copying files from the special files directory, copy the fresh 5.04
versions to other files with a ".o" (for "original") extension in case there
are problems later. For example, copy /etc/inittab to /etc/inittab.o.
17. Restore the /etc/hosts file from the special files directory. Test the
TCP/IP network; all connected PC's should now function.
18. Install the Equinox 3.32c serial port driver from diskette, using custom.
Relink the kernel. Restore the /etc/inittab, /etc/ttytype files from the
special files directory. Disable the multiconsole lines in /etc/inittab
temporarily. Reboot. Run Equinox ssdiag; make sure all previous settings
(including speed, flow control, transparent printing, and enabled or not
enabled) are correct. Test the serial terminals and transparent printing.
19. Copy the Boundless serialOsa, update, and Xsco files from the special file
directory to the appropriate directories and chown, chgrp, and chmod them (as
stated in the Boundless readme file). Then install the 3.07 driver (using the
interrupt and no. of multiscreens found in step 1) with Merge 4 fix using
custom. Relink kernel. Re-enable (if disabled) multiconsole lines in
/etc/inittab. Reboot. Run mkdev mouse to install the Sunriver mice (channel 0
serial port 1 is /dev/srs001, channel 1 serial port 1 is /dev/srs011, etc.).
Run mkdev graphics and add the Sunriver adapter (use 1024x768x256 colors, 70
Hz, 21" or whatever), and choose the appropriate no. of function keys for the
number of multiscreens. Relink kernel and reboot. Run srstat to check that
the configuration is correct. Enable the multiconsole units if not already
enabled (enable tty00a, tty00b, tty00c, tty00d,...,tty10a, tty10b, tty10c,
tty0d,..., etc.) Test the multiconsole units.
20. Install the three diskettes of Olympus Tuneup 6.0K using custom. Relink
kernel. Reboot. Run it and license it.
21. Do a second master CTAR backup of everything that has been done to this
step.
22. Copy the mustsave file from the special files directory back to the hard
drive, say to /usr/bin/. With the master backup tape in the tape drive (and
write-protected to be safe), use the following CTAR command (from root) to
restore all the files listed in the mustsave file:
ctar -xVNFfbk /usr/bin/mustsave /dev/rStp0 120 4194304
This accomplishes a non-destructive restore. (We don't want to do a
destructive restore because this may overlay operating system files, causing
innumerable problems.)
23. Install Arnet Fax software. Relink kernel. Configure it exactly as on
5.02, using the printout from /usr/spool/fax/faxconfig or copying the file from
the special files directory. Reboot. Check that the Arnet fax server has
started and that the corresponding fax modem works properly.
24. Install VSI-Gold Fax software. Configure it as before (copy the files
from the special files directory). Reboot. Test that the VSI-Fax server has
started and that the corresponding modem works properly.
25. Install the parallel port driver (using the interrupt from the hwconfig
printout). Restore all printer files from the special files directory. Using
Printer Manager, check that all printers are properly displayed and configured.
Test console printer (default). Log in to Novell via the Gateway and check
that Netware printers can print. Check that the multiconsole printers can
print. If there are problems, simply enter the printer information manually
from the configuration printouts.
26. Restore the /usr/lib/uucp/Devices file from the special files directory.
Check that the data modems are functioning properly.
27. Restore /etc/passwd from the special files directory. Reboot. Check that
all users can log in and function as before.
28. Restore /usr/spool/cron/crontabs/root. Reboot. Make sure that cron is
running.
29. Check application programs. If some files are missing, restore from
master diskettes. Check that X-desktops of users resemble what they were
before.
30. Perform Merge installation of Windows 3.1/3.11 for root; it should
recognize the Windows directory restored from tape. Check that all previous
Windows programs run correctly in an X-Window. Set Merge defaults to be same
as before. Check that autoexec.bat and config.sys function as before, e.g.,
logging into Novell with lccipx and netx and being able to use the CDROM drive
as drive K; they may have to be modified to work with Merge 4.
31. Make another CTAR backup of everything that has been done up to this step.
Make a new set of emergency boot and root diskettes.
32. Shutdown, reboot, and test every PC, terminal, multiconsole unit, modem,
and printer one more time.
33. Run Tuneup to re-tune the system (hopefully it will be able to use
information from the 5.02 history).
34. From SCO's Web-site, obtain all appropriate registration numbers. Enter
the information in the license manager.
--------
...and similarly for a fresh install now.
RWS
transpower@aol.com
- Next message: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Previous message: Yves Leclerc: "Re: Using ttyvc0 device name instead of tty01"
- In reply to: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Next in thread: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Reply: tony_at_aplawrence.com: "Re: Merge Installation/Configuration Problem on OpenServer 5.0.7"
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Relevant Pages
|