Re: Sun Fire V210 - unexpected SCSI interrupt while idle (at boot time)

From: Zii Ell (withheldxpx_sloewenthal##w3i34t7h54e56l1d_at_remove_this_bit_gemini_.remove_this_b)
Date: 11/20/03


Date: Thu, 20 Nov 2003 16:32:14 -0300

Update:

I swapped out the 2.9 disc and replaced it with a 2.8 Sun pre-installed disc
from another SunFire. The system booted and completed the system config.

Hwoever, when booting with the 2.8 disc I still get the

WARNING: /pci@1c,600000/scsi@2 (glm0):

unexpected SCSI interrupt while idle

error message, but the system still boots OK.

What does this "Cannot assemble drivers for root
/pci@1c,600000/scsi@2/disk@0,0:a" mean?

Cheers, Z.

"Zii Ell"
<withheldxpx_sloewenthal##w3i34t7h54e56l1d@remove_this_bit_gemini_.remove_th
is_bit_edu> wrote in message news:bpiu5f$1cb4$1@news.wplus.net...
> Hi there all,
>
> I have inherited a new SunFire. I've been told that its disc was
> pre-installed with Sol.2.8 and then jumpstarted with a fresh 2.9
> installation. After the 2.9 installation the system enters a continious
> reboot cycle with a SCSI error. I have included the info below. Although
> this is a SCSI error, I wonder if this is a problem with the disc or the
> rest of the machine?
>
> Regards, Zii.
>
> Sun Fire V210, No Keyboard
> Copyright 1998-2002 Sun Microsystems, Inc. All rights reserved.
> OpenBoot 4.8.2, 512 MB memory installed, Serial #54395873.
> Ethernet address 0:3:ba:3e:3:e1, Host ID: 833e03e1.
>
>
>
> Rebooting with command: boot
> Boot device: disk:a File and args:
> SunOS Release 5.9 Version Generic_112233-07 64-bit
> Copyright 1983-2003 Sun Microsystems, Inc. All rights reserved.
> Use is subject to license terms.
> WARNING: /pci@1c,600000/scsi@2 (glm0):
> unexpected SCSI interrupt while idle
> Cannot assemble drivers for root /pci@1c,600000/scsi@2/disk@0,0:a
> Cannot mount root on /pci@1c,600000/scsi@2/disk@0,0:a fstype ufs
>
> panic[cpu0]/thread=140a000: vfs_mountroot: cannot mount root
>
> 0000000001409970 genunix:vfs_mountroot+70 (0, 0, 0, 200, 1456d68, 0)
> %l0-3: 000000000144a800 000000000144a800 0000000000002000
0000000001498510
> %l4-7: 0000000001496000 0000000001411be8 000000000144b000
000000000144e000
> 0000000001409a20 genunix:main+98 (1409ba0, f0059b44, 1409ec0, 340653,
2000,
> 500)
> %l0-3: 0000000000000001 0000000000000000 0000000001412c80
0000000078002000
> %l4-7: 000000000140a000 0000000000342000 000000000149e500
0000000001062db0
>
> skipping system dump - no dump device configured
> rebooting...
>
> SC Alert: Host System has Reset
>
>



Relevant Pages

  • Problems setting up StorEdge 3310 on V240
    ... We have a new SUN V240 & a SUN StorEdge 3310 SCSI array. ... It appears as a single extra disc under ... All attempts to newfs of fsck c1t0d0s6 fail. ...
    (SunManagers)
  • Re: ISS sightings
    ... Calcsky will filter out Sun disk transits for the ISS. ... observing the suns disc and taking note of small birds and other ... I saw large birds too...hawks for fleeting moments. ...
    (sci.astro.amateur)
  • Re: 15 of my favorites so far in 06.
    ... January Sun is my favorite track also, ... I guess with me the VP is a given as far as it being my fave. ... It is a fantastic disc. ...
    (rec.music.artists.queensryche)
  • Re: Photo of the year
    ... against the disc of the sun with a highlighting sunspot. ... is subsequently showed up on APOD. ...
    (sci.astro.amateur)
  • Moving a boot disc from SunFire v120 to SunFire v210 [Our NIS+ RMS has failed]
    ... We have a spare SunFire v210 and I would like to ... take the dead machine's boot disc out of the V120 and put into the V210. ...
    (SunManagers)